Equipment Required; Procedure - Enfora Enabler LPP G Integration Manual

Table of Contents

Advertisement

7.8.2. Equipment required

Temperature chamber
Mostly discharged battery or battery simulator.
A notebook or desktop computer with any version of Microsoft Windows that has the
HyperTerminal communications program. If this hardware is not available, the user could use
a DOS terminal emulation program.

7.8.3. Procedure

This is a procedure for setting the AT$BCITMP# parameters, assuming a 10kohm NTC
temperature sense resistor is used.
Step
Action
1
Set
temperature
averaging.
2
Set current
to 30uA
3
Reset the
modem
4
Start debug
traces
5
Cycle
charger off,
on.
6
Ensure
battery is
charging
7
Set temp.
8
Set
temperature
parameters
9
Restore
averaging
10
Reset the
modem
11
Verify
temperature
readings
Repeat procedure for AT$BCITMP2-AT$BCITMP5, as required.
LPP0108IG001
Command
AT$BCIAVG=
<alfaV>,0,<alfaI>,<sampling>
(Note original value for later.)
AT$BCITMP#=-
20,60,x,x,x,x,x,x,x,x,x,30
AT$RESET
AT$BCIDBG=2,0.
AT$BCIOFF=1,
AT$BCIOFF=0
4(CCI) mode or 6(CVI) mode
Read Tbat=xxxx
(Note: This Tbat is a hex value
(Tbat)
).
16
AT$BCITMP#=-20,60,<adc@-20>,
<adc@-10>,<adc@0>,<adc@+10>,
<adc@+20>,<adc@+30>,<adc@+40>,
<adc@+50>,<adc@+60>,30
AT$BCIAVG=<alfaV>,<alfaT>,<alfaI>,
<sampling>
AT$RESET
AT$BAT=<pct>,<bat_id>,<chg_id>,
<state>,<Vbat>,<Ichg>,
(Note: This Tbat is a decimal value
(Tbat)
).
10
48
Equip.
Setting
V
<
BAT
4.2V
T
=-20C
CH
T
=-10C
CH
T
=0C
CH
T
=10C
CH
T
=20C
CH
T
=30C
CH
T
=40C
CH
T
=50C
CH
T
=60C
CH
T
=-20C
CH
<Tbat>
T
=25C
CH
T
=60C
CH
Version - Preliminary – 06/20/08
Calculation
<adc@-20> = (Tbat)
10
<adc@-10> = (Tbat)
10
<adc@0> = (Tbat)
10
<adc@+10> = (Tbat)
10
<adc@+20> = (Tbat)
10
<adc@+30> = (Tbat)
10
<adc@+40> = (Tbat)
10
<adc@+50> = (Tbat)
10
<adc@+60> = (Tbat)
10
Tbat = T
+/- 5C