Operating Power; Typical Input Current; Gsm Transmit Power - Enfora Enabler LPP G Integration Manual

Table of Contents

Advertisement

5.3. Operating Power

The Enfora Enabler LPP G module requires an input voltage of 3.3 Vdc to 4.5 Vdc.

5.3.1. Typical Input Current

Test Conditions:
Typical Results @ 3.8V, 20 deg C, terminated into a 50 load.
GSM Operation
Band
Mode
1900
1800
1 RX/1 TX, Full Power
900
850
Idle
ALL
GPRS Operation
Band
Mode
4 RX/1TX, Full Power
2 RX/2TX, Full Power
1900
1 RX/1TX, Full Power
4 RX/1TX, Full Power
2 RX/2TX, Full Power
1800
1 RX/1TX, Full Power
4 RX/1TX, Full Power
2 RX/2TX, Full Power
900
1 RX/1TX, Full Power
4 RX/1TX, Full Power
2 RX/2TX, Full Power
850
1 RX/1TX, Full Power
Idle
ALL

5.3.2. GSM Transmit Power

Enfora Enabler LPP G module
1900 MHz
1800 MHz
850 MHz
900 MHz
LPP0108IG001
Input Current
Low
Nom/Avg
21
21
21
21
Input Current
Low
15
15
15
15
15
15
15
15
15
15
15
15
Power Class
GSM Power Class 1
GSM Power Class 4
Version - Preliminary – 06/20/08
20
High/Peak
240
1180
245
1280
287
1600
265
1600
6.5
Nom/Avg
High/Peak
269
1180
375
1180
227
1180
271
1280
381
1280
230
1280
313
1600
473
1600
274
1600
300
1600
455
1600
264
1600
7.3
Transmit Power
1-W conducted power maximum (30
dBm +/- 2 dB), measured at the
antenna port
2-W conducted power
maximum (33 dBm +/- 2 dB),
measured at the antenna port
Units
mA
mA
mA
mA
Units
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA
mA

Advertisement