Mindray BeneVision TD60 Quick Reference Manual

Mindray BeneVision TD60 Quick Reference Manual

Display telepack

Advertisement

BeneVision TD60
Display Telepack
Q u i c k R e fe re n ce G u i d e

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BeneVision TD60 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Mindray BeneVision TD60

  • Page 1 BeneVision TD60 Display Telepack Q u i c k R e fe re n ce G u i d e...
  • Page 2 Note: The TD60 Quick Reference Guide is not intended as a replacement to the Operating Instructions. Prior to operating equipment, the user must be familiar with the Operating Instructions Manual contents. This document is a guideline only to be used as an aid to comprehensive Inservice Training.
  • Page 3: Table Of Contents

    Table of Contents TD60 Physical View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General Navigation .
  • Page 4 Table of Contents (cont'd) Pair a TD60 with a BP10 ..........14 Pair a TD60 with a New BP10 .
  • Page 5: Td60 Physical View

    BeneVision TD60 Quick Reference Guide TD60 PHYSICAL VIEW 1. Display Activation (Power On/Off ) key When the TD60 is powered off • Pressing this key will turn the TD60 on. When the TD60 is powered on • And the screen display is on, pressing this key will turn the display off.
  • Page 6 BeneVision TD60 Quick Reference Guide 4. Display Touch screen display for viewing patient information and adjusting patient settings. 5. Patient alarm light indicator 6. ECG lead connector 7. SpO Covers SpO connector when SpO is not in use. 8. SpO...
  • Page 7: General Navigation

    BeneVision TD60 Quick Reference Guide GENERAL NAVIGATION Swipe for More Data P/N: H-046-007060-00 Rev 3.0...
  • Page 8: View More Data

    BeneVision TD60 Quick Reference Guide View More Data The TD60 provides the following shortcuts to access additional information, as shown in the following figure: • Tap to enter the Patient Info menu • Tap to to view the MPAN info • Tap...
  • Page 9: Quick Key/Screen Menu Bar Deployment

    BeneVision TD60 Quick Reference Guide Quick Key/Screen Menu Bar Deployment Note: The quick keys are configurable. This image is just representative. P/N: H-046-007060-00 Rev 3.0...
  • Page 10: Patient Setup

    BeneVision TD60 Quick Reference Guide PATIENT SETUP Admit When admitting a TD60 for the first time, the device must be admitted to the system through the CMS. After first admitting the device to the CMS, you can directly admit the next patient on the TD60 by discharging the previous patient, and then pressing to admit a new patient.
  • Page 11: Standby

    BeneVision TD60 Quick Reference Guide To adjust the patient category: 1. Press to enter the main menu. 2. Tap Patient Info. 3. Tap Patient Category to select the patient category. 4. Select Yes to confirm that the patient category should be changed The selected patient category displays to the right of Patient Category.
  • Page 12: Resume Monitoring

    BeneVision TD60 Quick Reference Guide Resume Monitoring • Restores patient's settings, resumes alarm notification on the TD60 and the CMS. • Alarm system is activated. • The TD60 notifies the CMS of returning to Monitoring mode. To exit Standby mode: Press to exit Standby mode.
  • Page 13: Ecg

    BeneVision TD60 Quick Reference Guide Select ECG Leadwire The TD60 allows the clinician to set the ECG Leadwire Type being used. To configure the ECG Leadwire Type: • On the main screen, tap the HR digital area or ECG waveform area to enter the ECG menu.
  • Page 14: Enable Pacer

    BeneVision TD60 Quick Reference Guide The Lead Placement window indicates the lead status. Information bar Lead on indicator Lead off indicator When any of the leads are off, the indications are as follows: • The lead off message displays on the information bar.
  • Page 15: Resp

    BeneVision TD60 Quick Reference Guide RESP (OPTIONAL) Set NCM Alarm Delay The TD60 allows configuring the desired time for NCM Alarm Delay. When the patient has stopped breathing for longer than the set NCM Alarm Delay time, the TD60 will trigger the "No Chest Movement" alarm.
  • Page 16: Spo 2 (Optional)

    BeneVision TD60 Quick Reference Guide (OPTIONAL) The TD60 allows continuous pulse oximetry. Connect the SpO Module Connect the SpO module to the TD60 as shown in the following figure. module sensor connector sensor Connecting the Masimo SpO module P/N: H-046-007060-00 Rev 3.0...
  • Page 17: Initiate The Spo

    BeneVision TD60 Quick Reference Guide module sensor connector sensor Connecting the Nonin SpO module Initiate the SpO Measurement 1. Connect the sensor to the SpO module and the SpO module to the TD60. 2. Select an appropriate sensor according to the patient size, and weight.
  • Page 18: Nibp (Optional)

    BeneVision TD60 Quick Reference Guide NIBP (OPTIONAL) The TD60 allows non-invasive blood pressure (NIBP) monitored by a BP10 NIBP module. Pair a TD60 with a BP10 1. Press the MPAN key on the right panel of the BP10. The“Pairing... ”...
  • Page 19: Unpair A Td60 With A Bp10 Via The Td60

    BeneVision TD60 Quick Reference Guide Unpair a TD60 with a BP10 via the TD60 Option 1: 1. Press to enter the main menu. 2. Tap Wireles Modules. 3. Select the device you wish to disconnect from the TD60 from the devices list under Devices and tap Disconnect.
  • Page 20: Screen Display

    BeneVision TD60 Quick Reference Guide When Alarm Reset is configured as a Quick key, you can 1. Swipe up your finger at the bottom of the main screen to display the quick keys area. 2. Tap the Alarm Reset quick key.
  • Page 21: Adjust Display Order

    BeneVision TD60 Quick Reference Guide Adjust Display Order The TD60 allows the clinician to adjust the parameter order on the main display. To adjust the display order: 1. Press to enter the main menu. 2. Tap Display Setup. 3. To set portrait display orientation, tap Portrait Order.
  • Page 22: Unlock The Screen In Locked Mode

    BeneVision TD60 Quick Reference Guide Unlock the Screen in Locked Mode 1. If the display is off, press to activate the display and access the Screen Locked menu. 2. Enter the passcode to unlock the screen. Once the passcode is entered the screen is temporarily unlocked. If the clinician turns off the TD60 or the display times out, the passcode will need to be re-entered.
  • Page 23: Parameter Colors

    BeneVision TD60 Quick Reference Guide PARAMETER COLORS The TD60 provides the ability to adjust the parameter's numeric and waveform (if applicable) color. To adjust the parameter's color at the TD60: 1. Press to enter the main menu. 2. Tap Parameter Setup.
  • Page 24 BeneVision TD60 Quick Reference Guide The following table lists approved cleaning and disinfecting agents. Product Name Product Type Ingredients Sodium hypochlorite Liquid Sodium hypochlorite bleach 10% bleach* Hydrogen peroxide* Hydrogen peroxide 3% Isopropanol* Isopropanol 70% 1-Propanol* 1-Propanol 50% CIDEX OPA Solution Ortho-Phthalaldehyde 0.55%...
  • Page 25 BeneVision TD60 Quick Reference Guide Product Name Product Type Ingredients Alpet® D2 Surface Wipes Isopropyl Alcohol 58.6000%® Sanitizing Wipes Octyl Decyl Dimethyl Ammonium chloride 0.0075%, Dioctyl Dimethyl Ammonium Chloride 0.0030% Clorox Dispatch® Sodium Hypochlorite 0.65% Hospital Cleaner Disinfectant Towels with Bleach Clorox Sodium Hypochlorite 0.55%...
  • Page 26: Disinfect The Td60

    BeneVision TD60 Quick Reference Guide Product Name Product Type Ingredients PDI Sani-Cloth® Plus Wipes n-Alkyl dimethyl ethylbenzyl Germicidal Disposable ammonium chlorides 0.125%, Cloth n-Alky dimethyl benzyl ammonium chlorides 0.125% PDI Super Sani- n-Alkyl dimethyl ethylbenzyl Cloth®Germicidal ammonium chlorides 0.25%, Disposable Wipe* n-Alkyl dimethyl benzyl ammonium chlorides 0.25%,...
  • Page 27: Clean/Disinfect Reusable Accessories

    BeneVision TD60 Quick Reference Guide CLEAN/DISINFECT REUSABLE ACCESSORIES To clean and disinfect reusable ECG leadwires and SpO sensors, refer to the instructions for use delivered with the accessory. STERILIZATION Sterilization is not recommended for this equipment, related products, accessories or supplies unless otherwise indicated in the instructions for use delivered with the products, accessories or supplies.
  • Page 28 Mindray DS USA, Inc. 800 MacArthur Boulevard, Mahwah, New Jersey 07430 USA Tel: 1.800.288.2121, 1.201.995.8000 www.mindray.com 0 4 6 - 0 0 7 0 6 0 - 0 0 ( 3 . 0 )