Cardax Prox Mifare Series Installation Note page 9

Teardrop
Hide thumbs Also See for Prox Mifare Series:
Table of Contents

Advertisement

Connecting to the Cardax FT URI
Connect the cables to the socket as shown.
Prox Plus Mifare Connector
Connect the Prox Mifare Series (Teardrop) reader connector to either the P1 or
P2 plug on the Cardax FT URI. Refer to the Cardax FT URI component layout
diagram, next, for the location of the plugs.
P3
Keypad
pin 1 = Row1
pin 2 = Row 2
P2
pin 3 = Row 3
Non-CardaxFT
pin 4 = Row 4
pin 5 = Column1
Reader 2
pin 6 = Column2
pin 1 = 5/12 V power
pin 7 = Column3
pin 2 = DataA
pin 8 = Ground
pin 3 = DataB
pin 4 = Card detect
pin 5 = LED output
pin 6 = Beeper output
pin 7 = Ground
P2
P1
P1
Non-CardaxFT
Reader 1
pin 1 = 5/12 V power
pin 2 = DataA
pin 3 = DataB
pin 4 = Card detect
pin 5 = LED output
pin 6 = Beeper output
pin 7 = Ground
Part number 3E1100 R12
June 2007
Black
4
Blue
3
White
2
Red
1
F1
13.6 V Input Fuse
Rating = 500mA
P6
13.6 V ± 15%out
pin 1 = 13.6 V ± 15%
pin 2 = Ground 3A fused
F2
13.6 V Output Fuse
Rating = 3A
D19
JP2
D20
D15
D6
D5
R7
D4
Q2
D3
D2
P8
2
10
D1
1
9
(c)1999 PEC(New Zealand) Ltd
22825V2 Assy 22826
P8
Diagnostic port
Cardax FT Universal Reader Interface
Plug P1 or P2
D10
P5
Comms LED
Power & Comms
flashing = communicating with
pins 1 & 2 = RS485
FT Controller
pin 3 = 13.6 V ± 15%
pin 4 = 0V
E
D10
U19
T1
D22
D13
D12
D11
5V
12V
JP1
D16
D17
NC NO
COIL
Q7
COMM
D14
Q41
D21
NC NO
COIL
RLY2
COMM
Q26
D18
R53
D23
R50
Q27
R54
D24
R51
Q28
R55
D25
R52
Q29
R79
D26
R94
R80
Q30
D27
R95
R81
Q31
D28
R96
SW1
REV[A][B][C]
SW1
P4
Unit address
Balanced Inputs
Set unit number
pin 1 = Input1
pin 2 = Input 2
pin 3 = Input 3
pin 4 = Input 4
pin 5 = Input 5
pin 6 = Input 6
pin 7 = Ground
GND
OUTPUTS
OUTPUTS
DET
COMMS
COMMS
5/12V
JP1
Reader Voltage select
= 5V
(200mA total)
= 12V (1A total)
D17
D21
and
Relay state indicators
LED on = Energised
LED off = De-energised
P7
Relay Outputs
pin 1 = R1 Normally closed
pin 2 = R1 Normally open
pin 3 = R1 Common
pin 4 = R2 Normally closed
pin 5 = R2 Normally open
pin 6 = R2 Common
pin 7 = Ground
D18
Run LED
9

Advertisement

Table of Contents
loading

Related Products for Cardax Prox Mifare Series

Table of Contents