Cardax Prox Mifare Series Installation Note

Teardrop
Hide thumbs Also See for Prox Mifare Series:

Advertisement

Quick Links

Prox Mifare Series (Teardrop)
Before you Begin
Unpack the Prox Mifare Series (Teardrop) reader and check the shipment
contains the following items:
• 1 x Prox Mifare Series (Teardrop) reader base
• 1 x Prox Mifare Series (Teardrop) reader facia
• 1 x printed circuit board (PCB) assembly
• 1 x cable assembly
• 1 x M3 Torx Post Security screw
• 4 x self tapper pozi counter sunk fixing screws (two different lengths)
WARNING: You must use the screws provided, as using other types of
screws could interfere with the electronics. (See the "Mounting" section
later for further explanation.)
Power Supply Requirements
Power for the Prox Mifare Series (Teardrop) reader is usually taken from the
incoming supply of the device to which it is connected. That is, from the:
• Cardax FT Reader I/O Interface
• Cardax FT Controller 3000
• Cardax FT Universal Reader Interface (Cardax FT URI)
• Cardax Commander Universal Reader Interface (Cardax Commander URI).
The supply at the reader should be 13.6 V DC ± 15%. The current draw is 180
mA per reader. This is in addition to the requirements of any other device (for
example, the URI) powered from the same supply.
Part number 3E1100 R12
June 2007
This equipment contains components that can be damaged by
electrostatic discharge. Ensure both you and the equipment are
earthed before beginning any servicing.
Installation Note
CAUTION
1

Advertisement

Table of Contents
loading

Summary of Contents for Cardax Prox Mifare Series

  • Page 1 Power Supply Requirements Power for the Prox Mifare Series (Teardrop) reader is usually taken from the incoming supply of the device to which it is connected. That is, from the: • Cardax FT Reader I/O Interface •...
  • Page 2 120 pf/m. The maximum external diameter of the cable must not exceed 5 mm (1/5 inch). With this type of cable, the maximum distance between the Prox Mifare Series (Teardrop) reader and the device to which it connects is 200 m (650 ft).
  • Page 3 Therefore any imperial measurements provided are approximate only. The Prox Mifare Series (Teardrop) reader is designed to be mounted on any solid flat surface. However installation on metal surfaces, particularly those with a large surface area will reduce read range. The extent to which the range is reduced will depend upon the type of metal used.
  • Page 4 mounting surface to a minimum depth of 40 mm (1 in). Drill two pilot holes for the fixing screws. Run the building cabling through the base and grommet. Fit the base to the 20 mm ( inch) hole and secure it to the mounting surface using two of the fixing screws provided.
  • Page 5: Fcc Compliance

    Push the socket back into the grommet. Push the grommet and socket back into the Prox Mifare Series (Teardrop) reader base. Check the tape covering the antenna wire solder joints is in position. Install the PCB assembly into the base, ensuring the connector on the back of the PCB assembly fits into the socket in the base.
  • Page 6 Use the cable terminating tool to connect the cables to the socket as described in the following sections. Pin number 4 of the Prox Mifare Series (Teardrop) reader connector feeds into the cable terminating tool first. Connecting to the Cardax FT Controller 3000...
  • Page 7 PB. For example, if you connect a Prox Mifare Series (Teardrop) reader to Port 1 of Group 1, Port 2 of Group 1 can only connect to another Cardax IV reader. The terminating resistors (J1 for Group 1, J2 for Group 2, etc.) must NOT be fitted for those groups to which Prox Mifare Series (Teardrop) readers are connected.
  • Page 8 The Cardax FT Reader I/O Interface has connections for up to sixteen Prox Mifare Series (Teardrop) readers or other Cardax IV readers. The Prox Mifare Series (Teardrop) reader connects to either plug PA or PB in Groups 1 to 8.
  • Page 9 5/12V Connect the Prox Mifare Series (Teardrop) reader connector to either the P1 or P2 plug on the Cardax FT URI. Refer to the Cardax FT URI component layout diagram, next, for the location of the plugs. 13.6 V Input Fuse...
  • Page 10 Universal Reader Interface Prox Plus Mifare Connector Plug P4 (Exit) or P5 (Entry) Black Blue White 1-CK 0-DT 5/12V Note: Refer to Cardax Commander URI Components, for the location of the Cardax Commander URI components. Part number 3E1100 R12 June 2007...
  • Page 11 3E1089) for initialisation instructions. Initialisation of the Cardax FT Controller 3000 does not require prior connection to the Prox Mifare Series (Teardrop) reader. The Prox Mifare Series (Teardrop) reader will be operational as soon as it is: • connected to a Cardax FT Controller 3000, and •...
  • Page 12: Check Software Version

    Note: If you are installing the Prox Mifare Series (Teardrop) reader to control a turnstile you should consult the turnstile manufacturer for details of the locking mechanism used. Push-Button Exit If the door has a push button exit, ensure the URI Exit terminal has the push-...
  • Page 13 Cardax Commander URI Components Please refer to the diagram below for the location of the Cardax Commander URI components. Fuse Fuses (Reader Power (Relay Lithium Battery Lithium Battery Jumper Supply) Contacts) 1 Top Row 2 Row 2 Comms 3 Row 3 &...
  • Page 14: Setting The Jumpers

    ENTRY jumpers set the voltage and card type of the reader connected to plug P5. EXIT jumpers set the voltage and card type of the reader connected to plug Set the Entry and Exit jumpers for the Prox Mifare Series (Teardrop) reader as shown below:...
  • Page 15: Setting The Dip Switches

    DIPSW2 DIPSW2 Reader 12345678 12345678 Prox Mifare Series (Teardrop) reader 00000000 00011000 only, no authorised exit Prox Mifare Series (Teardrop) reader 00000100 00011100 only, with authorised exit Prox Mifare Series (Teardrop) reader...
  • Page 16 A URI can be initialised without being connected to a Commander. Set DIPSW1:7 to ON. Present a Smart Card to the Prox Mifare Series (Teardrop) reader. Note: You must present the card within 30 seconds of setting DIPSW1:7 to ON. If you are initialising with two readers connected to the URI, you should present the card to the reader on URI plug P5.
  • Page 17: Technical Specification

    Note: All specifications are subject to appropriate installation. Routine maintenance and serviceable parts: Not applicable for a Cardax Prox Mifare Series (Teardrop) reader Cleaning: The Cardax Prox Mifare Series (Teardrop) reader should only be cleaned with clean, lint free, damp cloth Power required: Voltage 13.6 ±...
  • Page 18: Mounting Dimensions

    Mounting Dimensions Pilot hole Slot 20 mm hole 39 mm 20 mm 51 mm 45 mm Pilot hole 17 mm Part number 3E1100 R12 June 2007...

Table of Contents