Cardax Prox Mifare Series Installation Note page 11

Teardrop
Hide thumbs Also See for Prox Mifare Series:
Table of Contents

Advertisement

Initialisation
Initialising with the Cardax FT Controller 3000
Refer to the Cardax FT Controller 3000 Installation Note (Part number
3E1089) for initialisation instructions.
Initialisation of the Cardax FT Controller 3000 does not require prior
connection to the Prox Mifare Series (Teardrop) reader. The Prox Mifare Series
(Teardrop) reader will be operational as soon as it is:
• connected to a Cardax FT Controller 3000, and
• configured as a Cardax IV reader within the Cardax FT Command Centre
system.
Initialising with the Cardax FT Reader I/O Interface
Refer to the Cardax FT Reader I/O Interface Installation Note (Gallagher Part
number 3E1016) for initialisation instructions.
Initialisation of the Cardax FT Reader I/O Interface does not require prior
connection to the Prox Mifare Series (Teardrop) reader. The Prox Mifare Series
(Teardrop) reader will be operational as soon as it is:
• connected to a Cardax FT Reader I/O Interface, and
• configured as a Cardax IV reader within the Cardax FT Command Centre
system.
Initialising with the Cardax FT URI
Refer to the Cardax FT Universal Reader Interface Installation Note
(Gallagher Part number 3C4518) for initialisation instructions.
Initialisation of the Cardax FT URI does not require prior connection to the
Prox Mifare Series (Teardrop) reader. The Prox Mifare Series (Teardrop)
reader will be operational as soon as it is:
• connected to a Cardax FT URI, and
• configured as a Cardax IV reader within the Cardax FT Command Centre
system.
Initialising with the Cardax Commander URI
Type of Door Lock
Depending on the type of lock fitted to the door that the reader is controlling,
you will need to initialise the URI with the door either closed or open.
If you initialise the URI with the door held open, it sets the door to unlock and
remains unlocked until the door is fully closed again. If you initialise the URI
with the door closed it sets the door to unlock and resets to lock as soon as the
door is opened.