Setting the Jumpers

Tamper the URI by opening the door of the cabinet. This releases the tamper
switch.
The URI has a set of six jumpers grouped into two sets of three. One group is
labelled ENTRY and the other is labelled EXIT.
ENTRY jumpers set the voltage and card type of the reader connected to plug
P5. EXIT jumpers set the voltage and card type of the reader connected to plug
P4.
Set the Entry and Exit jumpers for the Prox Mifare Series (Teardrop) reader as
shown below:
Confirmed Entry
Connector J2 on the URI controls the Confirmed Entry function. If you
initialise the URI with no jumper fitted on J2 the Confirmed Entry function
will be ON. To switch the Confirmed Entry function OFF, you must initialise
the URI with a mini-jumper fitted across both pins of connector J2.

Connecting the Reader

Connect the Prox Mifare Series (Teardrop) reader to the URI Entry Plug P5.
Note:
If you are using two entry readers (2 door software) you must connect the
second entry reader to URI Plug P4 to initialise the URI. Ensure Entry and Exit
jumpers are set to the same configuration.
If you are only using an Exit reader you must connect the reader to the Entry
Plug P5 to initialise the URI. After you have initialised the URI you should
connect the Exit reader to URI Exit Plug P4.
14
Entry and Exit Jumper Settings
Cardax
12 V
1
2
3
4
5
6
= jumper in place
Pins 3 and 6 = voltage supplied to reader
Pins 1,2 4 and 5 = reader type
Part number 3E1100 R12