[c] DIMPLE SIZE ADJUSTMENT
* The dimple size is factory adjusted to "1" (small).
* When the dimple size is adjusted to "3" (large), the freeze cycle will be shorter and allow
production of a large amount of ice in a short time.
1) Press the Dimple Size Button on the Operation Panel. The Display will show the current
setting.
2) Keep pressing the Dimple Size Button to change the setting.
Dimple Size
Freeze Cycle
2. SHUT DOWN
[a] SHUT DOWN
In case of low water, follow the steps 1 through 4 below.
1) Close the Water Supply Line Shut-off Valve.
2) Remove the Front Cover, and press the Reset Button. See "1. [b] REMOVAL OF
FRONT COVER".
3) Open the Door, and push the Bin Control Switch Lever located in the back right side of
the Storage Bin to the right for 60 seconds.
4) When the Display shows the "bin full" indication, turn off the Power Switch (Earth
Leakage Circuit Breaker).
5) Unplug the unit.
6) Replace the Front Cover in its correct position. See "1. [b] REMOVAL OF FRONT
COVER".
7) Remove all ice from the Storage Bin, clean the interior and exterior, and dry well.
1 - Small
2 - Medium
Longer
IMPORTANT
10
3 - Large
Shorter