[e] AIR FILTER (BIWEEKLY)

* If the Air Filter is clogged with dirt or dust, the icemaker cannot operate properly.
* Do not operate the icemaker with the Air Filter removed. Dust may come into the unit,
resulting in failure.
1) Remove the Front Cover. Pull the Air Filter toward
you, and lift it off. See "1. [b] REMOVAL OF FRONT
COVER".
2) Dilute a neutral detergent in cold or warm water. Wash
the Air Filter carefully not to break the mesh. Rinse and
dry well.
3) Fit the tab at the Air Filter bottom into the hole in the
Front Cover, and fix the Air Filter in place with the
magnet at the top.

2. INSPECTION

[a] SAFETY INSPECTION BY SERVICE PERSONNEL

Even if there is no problem with its use, a product out of warranty may have a risk of
electric shock, fire, or water leak due to insulation degradation or aging of the electrical
parts. Ask an authorized Hoshizaki service company for the following inspections (charged):
* Dust and dirt buildup or water leak inside the unit
* Aging conditions of the unit and its components
* Scale, silica, lime or other foreign matter in the water circuit

[b] EARTH LEAKAGE CIRCUIT BREAKER (MONTHLY)

Open the Front Cover, and press the Test Button with
the tip of a ball-point pen or the like. The lever must
move to the "OFF" position.
If the lever does not move to the "OFF" position, immediately contact an
authorized Hoshizaki service company.