Item
Panel tuning mode
*6: Because Open squelch (NXDN Narrow) is adjusted by adjusting Open squelch (Analog Narrow), it is not necessary to adjust Open squelch (NXDN
Narrow).
6. Low RSSI
1) Adj item: [LRSS]
at -118dBm
Adjust: []
*7
2) Adj item:
[L.RSS]
[Analog
[L.R.SS]
Narrow]
[L.R.S.S]
[L.R.S.S.]
[L.R.S.S._.]
SSG output:
-118dBm (0.28uV)
(MOD: 1kHz/±1.5kHz)
[Analog
1) Adj item: [LRSS]
Adjust: []
Wide 4k]
2) Adj item:
[L.RSS]
[L.R.SS]
[L.R.S.S]
[L.R.S.S.]
[L.R.S.S._.]
SSG output:
-118dBm (0.28uV)
(MOD: 1kHz/±2.4kHz)
[Analog
1) Adj item: [LRSS]
Wide 5k]
Adjust: []
2) Adj item:
[L.RSS]
[L.R.SS]
[L.R.S.S]
[L.R.S.S.]
[L.R.S.S._.]
SSG output:
-118dBm (0.28uV)
(MOD: 1kHz/±3kHz)
[NXDN
1) Adj item: [LRSS]
Very Nar-
Adjust: []
2) Adj item:
row]
[L.RSS]
[L.R.SS]
[L.R.S.S]
[L.R.S.S.]
[L.R.S.S._.]
SSG output:
-118dBm (0.28uV)
(MOD: 1kHz/±1.5kHz)
*7: Because Low RSSI at –118dBm (NXDN Narrow) is adjusted by adjusting Low RSSI at –118dBm (Analog Narrow), it is not necessary to adjust Low
RSSI at –118dBm (NXDN Narrow).
ADJUSTMENT
Condition
PC test mode
equipment
1) Adj item:
SSG
[Low RSSI (Analog
Narrow)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output:
–118dBm (0.28µV)
(MOD: 1kHz/±1.5kHz)
1) Adj item:
[Low RSSI (Analog
Wide 4k)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output:
–118dBm (0.28µV)
(MOD: 1kHz/±2.4kHz)
1) Adj item:
[Low RSSI (Analog
Wide 5k)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output:
–118dBm (0.28µV)
(MOD: 1kHz/±3kHz)
1) Adj item:
[Low RSSI (NXDN
Very Narrow)]
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
SSG output:
–118dBm (0.28µV)
(MOD: 1kHz/±1.5kHz)
Measurement
Test-
Unit
Terminal
Unit
ANT
Ext.SP
con-
nector
NX-720(G)/720
Adjustment
Parts
Method
[Panel tuning mode]
After input signal
from SSG, press
[
] key to store
the adjustment
value.
[PC test mode]
After input signal
from SSG, press
[Apply] button
to store the
adjustment value.
Adjust with the ana-
log signal.
Specifi cations/