Kenwood NX-720 Service Manual page 45

Vhf digital transceiver
Hide thumbs Also See for NX-720:
Table of Contents

Advertisement

Item
Panel tuning mode
2. High
1) Adj item: [HPWR]
Transmit
Adjust: []
Power
2) Adj item:
[H.PWR_]
[H.P.WR_]
[H.P.W.R_]
[H.P.W.R._]
[H.P.W.R._.]
PTT: ON
Press [
] key to
store the adjust-
ment value.
Low
1) Adj item: [LPWR]
Transmit
Adjust: []
power
2) Adj item:
[L.PWR_]
[L.P.WR_]
[L.P.W.R_]
[L.P.W.R._]
[L.P.W.R._.]
PTT: ON
Press [
] key to
store the adjust-
ment value.
3. Balance *2
1) Adj item: [BAL]
Adjust: []
Deviation meter
LPF: 3kHz
HPF: OFF
2) Adj item:
[B.AL_]
[B.A.L__]
[B.A.L.__]
[B.A.L._._]
[B.A.L._._.]
Adjust: []
PTT: ON
Press [
] key to
store the adjust-
ment value.
*2: Refer to the "Necessary Deviation adjustment item for each signaling and mode" table on page 50.
Balance adjustment is common with the adjustment of all signaling deviations.
4. Maximum
1) Adj item: [NDEV]
Deviation
Adjust: [.]
(NXDN) *3
Deviation meter
LPF: 3kHz
[Narrow]
HPF: OFF
PTT: ON
Press [
] key to
store the adjust-
ment value.
ADJUSTMENT
Condition
PC test mode
equipment
1) TEST CH:
Power
Low, Low', Center,
meter
High', High (5 point)
Ammeter
2) Transmit
Press [Apply All]
button to store the
adjustment value.
1) TEST CH:
Low, Low', Center,
High', High (5 point)
2) Transmit
Press [Apply All]
button to store the
adjustment value.
1) Adj item: [Balance]
Deviation
Deviation meter
meter
LPF: 3kHz
Oscillo-
HPF: OFF
scope
2) Adj item: [Low],
[Low'], [Center],
[High'], [High]
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
[2kHz Sine Wave
Check box]: Check
while transmitting
change to 2kHz.
1) Adj item: [Maximum
Deviation
Deviation (NXDN
meter
Narrow)]
Oscillo-
Deviation meter
scope
LPF: 3kHz
HPF: OFF
PTT: Press
[Transmit] button.
Press [Apply All]
button to store the
adjustment value.
NX-720(G)/720
Measurement
Test-
Unit
Terminal
Unit
ANT
ANT
ANT
Adjustment
Parts
Method
[Panel
25.0W
±1.0W
tuning
10.0A or less
mode]
[PC test mode]
[
],
Press [Apply All]
[
]
button to store the
[PC test
adjustment value
mode]
after all adjustment
point was adjusted.
[
],
[
]
5.0W
±0.2W
7.0A or less
[PC test mode]
Press [Apply All]
button to store the
adjustment value
after all adjustment
point was adjusted.
[Panel
The Deviation of
2kHz Tone deviation
tuning
20Hz frequency is
is within ±1.0% of
mode]
fi xed. Change the
20Hz tone deviation.
2kHz adjustment
[
],
value to become
[PC test mode]
[
]
the same deviation
Press [Apply All]
[PC test
of 20Hz within the
button to store the
mode]
specifi ed range.
adjustment value
after all adjustment
[
],
point was adjusted.
[
]
[Panel
Write Reference
2995~3117Hz
tuning
value "513" for
mode]
each adjustment
[PC test mode]
[
],
point. Transmit at
Press [Apply All]
each adjustment
button to store the
[
]
point and check
adjustment value
[PC test
that the Analog
after all adjustment
mode]
deviation is be-
point was adjusted.
tween 2995Hz and
[
],
3117Hz.
[
]
Specifi cations/
Remarks
45