Page 14
1. Manual locking:
The door is not locked automatically according to the selected time of day, but
instead only after an authorized transponder is operated after this time.
2. Automatic locking (default setting):
The door is locked at exactly the time stored in the time zone plan.
3. Manual unlocking (default setting):
The door is not unlocked automatically according to the selected time of day,
but instead only after an authorized transponder is operated after this time.
4. Automatic unlocking:
Normally, the door is not opened at the selected time of day, but instead only
after operation with the first transponder. If it is required that the door always
open automatically at the selected time of time, then select this option.
5. Transponder active:
- Always:
Normally, a transponder cannot be used during the released periods. If it is
necessary, however, to be able to lock the door during this time (for example,
if everyone leaves the building), then select this option.
- Only when locked:
In this operating mode, the transponder has no effect during the released
time.
7.7
OMRON
Only for SREL.ADV
Many access control and time recording systems have serial interfaces for connection
to card readers. It is also possible to connect a SmartRelay over these interfaces.
This means that you can also use the SimonsVoss transponder in systems from other
companies.
If you would like the SmartRelay to transmit the transponder data to such an external
system, and for the SmartRelay to send a remote opening command to a cylinder
when released by this external system, then select this option, both on the Smart
Relay and on the cylinder.
Select the type of external system under "Interface" (7.13). The following types are
available:
SmartRelay: SREL, SREL.ZK, SREL.ADV
Need help?
Do you have a question about the SmartRelay and is the answer not in the manual?
Questions and answers