Procedure To Clean Heavily Scaled Flake/Nugget Ice Machines - Manitowoc SF0406A Installation, Use & Care Manual

Nugget/flake ice machines
Table of Contents

Advertisement

Maintenance

PROCEDURE TO CLEAN HEAVILY SCALED FLAKE/NUGGET ICE MACHINES

Ice machines that are heavily scaled or have not been cleaned on a regular basis will need to run this Procedure.
Failure to do so may result in binding of the auger as the lime scale releases from the auger and evaporator barrel.
Step 1 Remove panels and set the ICE/OFF/CLEAN
toggle switch to the OFF position.
Step 2 Remove all ice from the bin.
Step 3 Turn off the water supply to the ice machine.
Step 4 Place ICE/OFF/CLEAN toggle switch in the
CLEAN position. The dump valve will open and drain the
water from the evaporator and reservoir.
Step 5
Wait approximately 30 seconds (or until the
evaporator is drained) and place the toggle switch in the
OFF position.
Step 6 Refer to chart and add the correct amount of
cleaner for your model ice machine.
Model
SF0400 SN0450
SF0600 SN0650
SF0900 SN0950
SF1200 SN1250
4-4
Amount of Cleaner
Part Number 000000084
12 ounces (355 ml)
12 ounces (355 ml)
12 ounces (355 ml)
24 ounces (710 ml)
Step 7 Turn on the water supply to the ice machine.
Leave the cleaner/water solution in the evaporator
for a minimum of 4 hours.
Step 8 Move the toggle switch to the ICE position. The
compressor will energize and produce ice with the
cleaning solution. Continue the freeze cycle for 15
minutes.
Step 9 Move the toggle switch to the OFF position,
then follow the standard cleaning and sanitizing
procedures (Pages 4-5 & 4-6).
Section 4
Important
Part Number 000001196 3/08

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents