C. Turn on main electrical power switch.
INSTRUCTIONS" found later in this manual.
D. Natural gas and liquefied petroleum gas fired dryers both operate in the same manner. When gas-valve
relay contacts are closed (indicating a demand for heat), the solid state ignition control will automatically supply
energy to the redundant gas valve. Spark will continue until a flame is detected by the sensing probe, but not
longer than 10 seconds. If the gas fails to ignite within 10 seconds, the gas will shut off for 15 seconds. The control
will attempt to ignite two more times in a similar manner. If the gas fails to ignite after three tries, the gas valve
closes and the system will "lock out". No further attempts at ignition will be performed automatically. It is then
necessary to interrupt electrical power to the ignition system before making another attempt to light the burners.
This can be done by opening the dryer door, allowing the dryer to come to a stop for 15 seconds, closing the door,
and pushing the "Start"
To render the dryer inoperative, turn off the main gas shut-off valve and disconnect electrical power to the dryer.
IT IS RECOMMENDED THAT THE INSTALLER TEST THE DRYER FOR OPERATION AND INSTRUCT THE
USER BEFORE LEAVING THE INSTALLATION.
8514-279-001 REV B PAGE 11
The dryer may be started by following the "OPERATING
button. The dryer will then repeat the ignition trial cycle.

DRYER SHUTDOWN