Summary of Contents for Baker Hughes Masoneilan SVI FF

  • Page 1 Masoneilan * SVI * FF Advanced Performance Digital Positioner Bench Quick Start (Rev Instruction Manual BHGE Data Classification: Public...
  • Page 2 All information contained herein is believed to be accurate at the time of publication and is subject to change without notice. Copyright 2019 by Baker Hughes, a GE company LLC. All rights reserved. PN 720036097-888-0000 Rev. E. © 2019 Baker Hughes, a GE company, LLC. All rights reserved.
  • Page 3: Bench Quick Start

    “3. Performing Basic Configuration” on page 11 “4. Optional Find Stops and Open Stops Adjustments” on page 12 “5. Perform Autotune” on page 14 Masoneilan SVI FF Bench Quick Start Manual © 2019 Baker Hughes, a GE company, LLC. All rights reserved.
  • Page 4: Physical Setup

    Any other pneumatic accessories are correctly piped without restricting the SVI FF output(s) to the actuator. 6. Plugging in the hub power supply and ensure the hub LED is green. © 2019 Baker Hughes, a GE company, LLC. All rights reserved. BHGE...
  • Page 5: Software Install And Configuration

    2. Download the SVI FF DTM and ValVue3 and install. See “Appendix B: Download Instructions” on page 16 for download site. ® You must have Windows administrator rights. Install the NOTE software as an administrator. © 2019 Baker Hughes, a GE company, LLC. All rights reserved. Masoneilan SVI FF Bench Quick Start Manual...
  • Page 6 No and you need to manually updated from the DTM Library Management dia- log to access any new functionality. ValVue version 3.30 or later. For earlier versions continue with manual DTM Library update. © 2019 Baker Hughes, a GE company, LLC. All rights reserved. BHGE...
  • Page 7 7. Click Settings > Field Networks, click Add and Figure 4 appears. Select the GE NI-FBUS-H1 Comm. DTM and click OK. Figure 4 Add Field Network © 2019 Baker Hughes, a GE company, LLC. All rights reserved. Masoneilan SVI FF Bench Quick Start Manual...
  • Page 8 Figure 6 Add New Device 10. Connect the SVI FF to the power hub leads. The connection is not polarity sensitive. 11. Highlight SVI FF and click OK. © 2019 Baker Hughes, a GE company, LLC. All rights reserved. BHGE...
  • Page 9 17. Click OK to the DTM evaluation period warning. The SVI FF DTM opens. BHGE recommends getting the advanced version of the DTM and NOTE registering your software. © 2019 Baker Hughes, a GE company, LLC. All rights reserved. Masoneilan SVI FF Bench Quick Start Manual...
  • Page 10 Upload means to pull data from the SVI FF and load data into DTM NOTE onto the PC. Download puts data from the DTM into the SVI FF. © 2019 Baker Hughes, a GE company, LLC. All rights reserved. 10 | BHGE...
  • Page 11: Performing Basic Configuration

    SVI FF DTM and on the Positioner State tab, clicking the Details button and setting the state back to Normal or by setting the parameter 86.APP_MODE to Normal. © 2019 Baker Hughes, a GE company, LLC. All rights reserved. | 11 Masoneilan SVI FF Bench Quick Start Manual...
  • Page 12: Optional Find Stops And Open Stops Adjustments

    2. For ATO actuator, perform an Open Stop Adjustment by: Use mechanical means, if available on the valve, to restrict the NOTE stops. If not available, use the Masoneilan software. © 2019 Baker Hughes, a GE company, LLC. All rights reserved. 12 | BHGE...
  • Page 13 Once all procedures are complete, you must put the SVI FF into NOTE Manual or Auto mode before returning to operations. © 2019 Baker Hughes, a GE company, LLC. All rights reserved. | 13 Masoneilan SVI FF Bench Quick Start Manual...
  • Page 14: Perform Autotune

    Supply pressure MUST NOT exceed the actuator pressure rating marked on the actuator. Positioner supply pressure MUST BE at least 5 psi higher than the upper spring range of the valve. © 2019 Baker Hughes, a GE company, LLC. All rights reserved. 14 | BHGE...
  • Page 15: Appendix A: Suggested Ni Hardware

    If you fail to switch the Transducer block to Auto, then the valve will not be in control. Appendix A: Suggested NI Hardware Figure 14 Suggested NI Hardware © 2019 Baker Hughes, a GE company, LLC. All rights reserved. | 15 Masoneilan SVI FF Bench Quick Start Manual...
  • Page 16: Appendix B: Download Instructions

    2. Select Download below ValVue Installer Download and Figure 16 appears. Figure 16 Opening Dialog The dialog that appears for download varies by the program used. NOTE © 2019 Baker Hughes, a GE company, LLC. All rights reserved. 16 | BHGE...
  • Page 17 1. Go to the Resource Library (www.valves.bhge.com/resource-center) and enter SVI FF in the search field. Figure 17 Download Center: Search for SVI FF DTM The results appear (red box in Figure 17). © 2019 Baker Hughes, a GE company, LLC. All rights reserved. | 17 Masoneilan SVI FF Bench Quick Start Manual...
  • Page 18 5. Double-click on the installer and follow the instructions to install. © 2019 Baker Hughes, a GE company, LLC. All rights reserved. 18 | BHGE...
  • Page 19: Appendix C: Dtm Versions

    Auto Tune Quick Wizard Full Wizard Diagnostics Step Test Ramp Test Signature Test Histograms Trends Identification Security Print Write Notes © 2019 Baker Hughes, a GE company, LLC. All rights reserved. | 19 Masoneilan SVI FF Bench Quick Start Manual...
  • Page 20 This page intentionally left blank.
  • Page 22 © 2019 Baker Hughes, a GE company, LLC. - All rights reserved. Baker Hughes, a GE company, LLC and its affiliates (“BHGE”) provides this information on an “as is” basis for general information purposes and believes it to be accurate as of the date of publication. BHGE does...

Table of Contents