  • Page 1 Masoneilan ™ Remote Position Sensor (RPS) Quick Start Guide (Rev. D) (For SVI II AP, SVI3 and SVI FF) ™ Baker Hughes Data Classification: Public...
  • Page 2 Copyright The complete design and manufacture of the Remote Position Sensor is the intellectual property of Baker Hughes. All information contained herein is believed to be accurate at the time of publication and is subject to change without notice. Copyright 2022 Baker Hughes company. All rights reserved.
  • Page 3 Reference to SVI II APN has been removed Reference to SVI3 has been added Reference to SMARTS Assistant configuration tool has been removed © 2022 Baker Hughes company. All rights reserved Masoneilan Remote Position Sensor Quick Start Guide =| 3...
  • Page 4: Table Of Contents

    Configuring the SVI FF for Remote Position Sensing: SVI FF DTM ....25 Configure for the Remote Position Sensor ............. 26 Configure for the Remote Position Sensor: Handheld ........ 27 4 | =Baker Hughes © 2022 Baker Hughes company. All rights reserved...
  • Page 5: Safety Information

    Indicates a potentially hazardous situation, which if not avoided could result in instrument or property damage, or data loss. Note: Indicates important facts and conditions. © 2022 Baker Hughes company. All rights reserved Masoneilan Remote Position Sensor Quick Start Guide =| 5...
  • Page 6: Remote Mount Product Safety

    Changes to specifications, structure, and components used may not lead to the revision of this manual unless such changes affect the function and performance of the product. 6 | =Baker Hughes © 2022 Baker Hughes company. All rights reserved...
  • Page 7: Introduction

    Note: For non-Masoneilan positioners: When the flat of the RPS output shaft is facing right (from the backside with the conduit opening facing down), the potentiometer is at the midusable travel range. © 2022 Baker Hughes company. All rights reserved Masoneilan Remote Position Sensor Quick Start Guide =| 7...
  • Page 8 Before carrying out any work on the device, power off the instrument or make sure that the local conditions for potentially explosive atmosphere permit the safe opening of the cover. 8 | =Baker Hughes © 2022 Baker Hughes company. All rights reserved...
  • Page 9: Connecting To Reciprocating Valves

    See “How to Check Raw Values” on page 18. Note: Note the orientation of the drawing and adjust as necessary if your orientation differs. © 2022 Baker Hughes company. All rights reserved Masoneilan Remote Position Sensor Quick Start Guide =| 9...
  • Page 10 5/16 inch flat washer  Figure 1 Mounting Bracket Mounting Holes Slide the bracket in to match the required mounting hole. See Table 3. Figure 2 Slide the Mounting Bracket In 10 | =Baker Hughes © 2022 Baker Hughes company. All rights reserved...
  • Page 11 Hex cap screws 5/16-18 UNC L=0.75  8 mm split lock washer  5/16 inch flat washer  Valve Figure 3 Attach Mounting Bracket to © 2022 Baker Hughes company. All rights reserved Masoneilan Remote Position Sensor Quick Start Guide =| 11...
  • Page 12 Place the 1/4 inch hex jam nut on the take off rod and loosely tighten. Figure 5 Connect the LH Rod End 12 | =Baker Hughes © 2022 Baker Hughes company. All rights reserved...
  • Page 13 -2A, 12.7 L). Two not shown. Align the lever with the indicating hole. The example shown is Air-to-Open. Figure 8 Attach the RPS to the Mounting Plate © 2022 Baker Hughes company. All rights reserved Masoneilan Remote Position Sensor Quick Start Guide =| 13...
  • Page 14 Brown to 2  Red to 1  Figure 11 SVI II AP Connections SVI3 REMOTE REMOTE 1-5Vdc 1-5Vdc Remote Posi on Sensor Remote Position Sensor Input Connections for SVI3 14 | =Baker Hughes © 2022 Baker Hughes company. All rights reserved...
  • Page 15 Refer to “Configuring the SVI II for Remote Position Sensing” on page 23 or “Configuring for SVI FF” on page 25 for required software and instruction for configuration. © 2022 Baker Hughes company. All rights reserved Masoneilan Remote Position Sensor Quick Start Guide =| 15...
  • Page 16 This page intentionally left blank. 16 | =Baker Hughes © 2022 Baker Hughes company. All rights reserved...
  • Page 17: Connecting To Rotary Valves

    Note: Note the orientation of the drawing and adjust as necessary if your orientation differs. © 2022 Baker Hughes company. All rights reserved Masoneilan Remote Position Sensor Quick Start Guide =| 17...
  • Page 18 Use a 3/16 inch hex key to install the mounting plate using the two flat head socket screws 5/16 inch-18UNC, 0.62 inch Long. Figure 14 Attach Mounting Bracket to Valve 18 | =Baker Hughes © 2022 Baker Hughes company. All rights reserved...
  • Page 19 3 mm hex key. Set screw must seat on flat of stem. Figure 16 RPS Side Lever © 2022 Baker Hughes company. All rights reserved Masoneilan Remote Position Sensor Quick Start Guide =| 19...
  • Page 20 RPS unit to the Mounting Plate using the four hex head cap screws (1/4 inch-20UNC -2A, 12.7 L). Plate Figure 18 Attach the RPS to the Mounting 20 | =Baker Hughes © 2022 Baker Hughes company. All rights reserved...
  • Page 21 Figure 20 SVI II AP Connec SVI3 REMOTE REMOTE 1-5Vdc 1-5Vdc Remote Posi on Sensor Remote Position Sensor Input Connections for SVI3 © 2022 Baker Hughes company. All rights reserved Masoneilan Remote Position Sensor Quick Start Guide =| 21...
  • Page 22 Figure 21 SVI FF Connec 1. Screw the cover on. 2. Use an 6mm hex key to tighten the locking screw. Locking screw Figure 22 Assemble Cover onto RPS Unit 22 | =Baker Hughes © 2022 Baker Hughes company. All rights reserved...
  • Page 23: Configuring For Svi Ii Ap And Svi3

    You must run a Find Stops and Autotune procedure after stetting up the Remote Position Sensor. Refer to SVI II AP or SVI3 DTM help manual for further instructions. © 2022 Baker Hughes company. All rights reserved Masoneilan Remote Position Sensor Quick Start Guide =| 23...
  • Page 24: Configuring The Svi Using Svi Ii Ap / Svi Dtm

    2. Use the position sensor pulldown to select: Internal Position Sensor, Remote Position or PV Analog Position Sensor. A warning dialog appears. Warning Dialog 3. Click to download to the device. 24 | =Baker Hughes © 2022 Baker Hughes company. All rights reserved...
  • Page 25: Configuring For Svi Ff

    SVI FF DTM. 4. Perform Autotune. Refer to SVI FF help or help print manual, which is installed with the SVI FF DTM. © 2022 Baker Hughes company. All rights reserved Masoneilan Remote Position Sensor Quick Start Guide =| 25...
  • Page 26: Configure For The Remote Position Sensor

    4.Click Man on the toolbar to switch to Manual mode ( in Figure 24). 5. Optionally, view and clear all positioner state faults. 6. Run Find Stops. 7. Run Autotune. 26 | =Baker Hughes © 2022 Baker Hughes company. All rights reserved...
  • Page 27: Configure For The Remote Position Sensor: Handheld

    Figure 25 All Menu 2. Cursor down the list and near the bottom tap on the command in Figure 25 and Figure 26 appears. © 2022 Baker Hughes company. All rights reserved Masoneilan Remote Position Sensor Quick Start Guide =| 27...
  • Page 28 Figure 26 Choose Remote Sensor 3. Use the down arrow to choose item 3. Enable Remote Sensor. Tap OK and the All menu reappears (Figure 27). Figure 27 All Menu: Send 28 | =Baker Hughes © 2022 Baker Hughes company. All rights reserved...
  • Page 29 4. Confirm SVIFF has been configured for Remote Sensor by using the NI Dialog Utility to view the Accessory Remote_Sensor setting (Figure 28). Figure 28 NI Dialog © 2022 Baker Hughes company. All rights reserved Masoneilan Remote Position Sensor Quick Start Guide =| 29...
  • Page 30 This page intentionally left blank. 30 | =Baker Hughes © 2022 Baker Hughes company. All rights reserved...
  • Page 31 This page intentionally left blank. © 2022 Baker Hughes company. All rights reserved Masoneilan Remote Position Sensor Quick Start Guide =| 31...
  • Page 32 Baker Hughes hereby disclaims any and all liability for any direct, indirect, consequential or special damages, claims for lost profits, or third party claims arising from the use of the information, whether a claim is asserted in contract, tort, or otherwise.

This manual is also suitable for:

Masoneilan svi3Masoneilan svi ff

Table of Contents