Startup Procedure - Safeline SL6+ Manual

Emergency lift telephones
Hide thumbs Also See for SL6+:
Table of Contents

Advertisement

Startup
procedure
NOTE: The unit will not start at
battery connection only.
1.
Upon startup: a tone se-
quence is heard in the system
speaker
2.
Check 230 VAC mains power.
3.
SL6+ main unit searches for
stations connected to the bus.
For every voice station found,
a beep sound is heard in the
system speaker.
1
2
3
4
5
6
Example: found all voice stations
except for number 3.
4.
Refer to chapter:
Troubleshooting voice station.
5.
When a working telephone
line is connected or a GSM net is
available, LED 3 is flashing green
every 5 seconds.
6.
Refer to chapter: Trouble-
shooting main unit.
Startup
Startup the SL6+
Connect the battery
Connect 230 VAC
SL6+ searches for
connected bus units
Number of beeps
SL6+ checks for valid
telephone line or GSM net
LED 3 flashing
16
LED 1
turns green?
OK?
green?
Startup ready
No 230 VAC
or broken unit
Unit communication
failure
No telephone line
or GSM net.
SL6+ v.3.30 EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SL6+ and is the answer not in the manual?

Subscribe to Our Youtube Channel

Table of Contents