Exchange Of The Magnesium Protection Anode - iDM iPump A 3-11 Technical Documentation Installation Instructions

Model: 400 v, 230 v with navigator 2.0. air heat pump with inverter-technology
Hide thumbs Also See for iPump A 3-11:
Table of Contents

Advertisement

1 0 .3. Exch a nge of t h e m ag n e si um pro t e c-
tio n a n od e
Before the anode is unscrewed, the buffer must be
emptied. The drain valve is located on the underside
of the buffer. For draining a hose must be connected.
In order to protect the underlying electric from any
escaping residual water, it is best to cover it with a
foil.
The black connection line between the anode and the
buffer must be terminated.
(C) IDM ENERGIESYSTEME GMBH
Then the anode can be unscrewed by a suitable pipe
wrench.
The used magnesium protective anode can now be
pulled out and replaced by a new one.
The new anode will be screwed fi rmly and the black
connection cable between the anode and the buffer
must be pluged.
After refi lling the buffer, it must be checked for leaks
in the area of the protective anode.
Installation instructions iPump A 3-11
magnesium protection anode
41