5
Mounting and electrical connection
5.2 Electrical connection
Carrying out electrical connections
Disconnect main power and protect against power up.
For safety instructions refer to chapter 2.
Connect power supply to terminals 1 and 2.
Terminal 2: 24V DC (+)
Terminal 1: Ground (-)
Connect motor to terminals MA and MB.
Polarity determines direction of operation.
Connect encoder.
Terminals 82, 86, 85 and 1
Connect on-site actuators (optional)
Terminals 1, 15, 21 and 29
12/26
Instruction Manual
C A U T I O N
Wrong installation
Damage of control device.
Observe polarity of connections.
Inputs (Terminals 1, 15, 21, 29) are potential free.
Figure 3
Control device inputs
Motor
Encoder
b
a
82
86
85
1
2 1
29
1
15
21
On-site
control
inputs
Slido Classic 80-B eDrive-Version 1.10n