WIKA LF-1 Operating Instructions Manual page 21

Submersible pressure sensor
Table of Contents

Advertisement

Available languages

Available languages

9. Specifications
Specifications
Accuracy (pressure sensor)
(at reference conditions)
Accuracy (temperature sensor)
Accuracy after turndown 5:1 via
HART
®
Non-linearity (per IEC 61298-2)
Non-repeatability
Temperature error
Long-term stability
(per DIN 16086:2006-01)
Reference conditions
Ambient temperature
Atmospheric pressure
Humidity
Power supply
Mounting position
Ingress protection
Insulation voltage
Resistance to overvoltage
Reverse polarity protection
Short-circuit resistance
WIKA operating instructions submersible pressure sensor, model LF-1
≤ ±1 % of span
≤ ±0.5 % of span (option)
-10 ... +80 °C [14 ... 176 °F]: ±1.8 K
-30 ... -10 °C [-22 ... +14 °F]: ±3.0 K
-40 ... -30 °C [-40 ... -22 °F]: ±4.5 K
≤ ±1.25 % of scaled span
≤ ±0.75 % of scaled span (option)
≤ ±0.5 % of span BFSL
≤ ±0.25 % of span BFSL (option)
≤ 0.1 % of span
≤ 0.2 % of span (with voltage output and cable length >100 m [325 ft])
see table "Temperature error"
Measuring range > 0 ... 0.1 bar: ≤ ±0.1 % of span/year
Measuring range ≤ 0 ... 0.1 bar: ≤ ±0.2 % of span/year
15 ... 25 °C [59 ... 77 °F]
860 ... 1,060 mbar [86 ... 106 kPa /12.5 ... 15.4 psig]
45 ... 75 % r. h.
DC 24 V with current output
DC 5 V with voltage output
Calibrated in vertical mounting position with protection cap thread facing downwards.
IP68
DC 850 V
Option of increased overvoltage protection for lightning strikes: DC 50 V
DC 40 V
U+ vs. U-
S+ vs. U-