11.4. Setting method

This section describes about setting for writing EPO data.
Setting file will be located at "internal storage\agps\agps.conf".
Locate created file according to below list.
11.4.1. Setting file agps.conf
File path: /mnt/sdcard/agps/agps.conf
Default: None It is generated with the default value when [Settings]-[AGPS data update] is
executed.
File format: Conform to notation of java.util.Properies
Use "\:" to write colon
No
Item
EPO_URL
1
EPO_NUM_SEGS
2
LAST_MOD
3
MOVERIO Pro Developer's Guide (Rev.1.4)
Table 11-1 Setting items in agps.conf
Set URL of EPO data delivery server.
Default value is" https://tech.moverio.epson.com/epo/data.bin"
Set EPO writing segment number(1~28).
1 segment =6 hours.
Default value is 28(6 hours ×28=7 days)
Shows download time of last time.
Not need for setting.