Hisense ADT-12UX4SSNL3 Technical & Service Manual page 114

Dc-inverter air conditioners, duct, cassette, ceiling & floor
Table of Contents

Advertisement

W
I
R
I
N
G
D
I
A
G
W
I
R
I
N
G
D
I
A
G
1
1
.
1
1
.
T [℃]
Rmin [ KΩ ]
11
9.199
12
8.826
13
8.470
14
8.129
15
7.804
16
7.493
17
7.196
18
6.912
19
6.640
20
6.381
21
6.132
22
5.894
23
5.667
24
5.449
25
5.240
26
5.048
27
4.864
28
4.687
29
4.517
30
4.355
31
4.198
32
4.048
33
3.904
34
3.766
35
3.663
36
3.506
37
3.383
38
3.265
39
3.152
40
3.043
41
2.938
42
2.838
43
2.741
44
2.648
45
2.558
46
2.472
47
2.389
48
2.309
49
2.232
50
2.158
51
2.087
52
2.018
53
1.952
54
1.888
DC-INVERTER AIR CONDITIONER TECHNICAL&SERVICE MANUAL
R
A
M
R
A
M
Rnom [ KΩ ]
9.422
9.047
8.689
8.347
8.021
7.709
7.412
7.127
6.855
6.595
6.347
6.109
5.882
5.664
5.456
5.260
5.072
4.891
4.717
4.550
4.390
4.236
4.089
3.946
3.810
3.679
3.552
3.431
3.314
3.202
3.094
2.990
2.890
2.793
2.701
2.611
2.525
2.443
2.363
2.286
2.212
2.140
2.072
2.005
Rmax [ KΩ ]
DR(MIN)%
9.647
-2.37
9.269
-2.44
8.910
-2.52
8.567
-2.61
8.240
-2.71
7.928
-2.80
7.630
-2.91
7.346
-3.02
7.074
-3.14
6.815
-3.24
6.567
-3.39
6.330
-3.52
6.103
-3.66
5.886
-3.80
5.678
-3.96
5.478
-4.03
5.286
-4.10
5.101
-4.17
4.924
-4.24
4.753
-4.29
4.589
-4.37
4.431
-4.44
4.280
-4.52
4.134
-4.56
3.994
-3.86
3.859
-4.70
3.729
-4.76
3.604
-4.84
3.484
-4.89
3.368
-4.97
3.257
-5.04
3.149
-5.08
3.046
-5.16
2.946
-5.19
2.850
-5.29
2.758
-5.32
2.669
-5.39
2.583
-5.49
2.500
-5.54
2.421
-5.60
2.344
-5.65
2.269
-5.70
2.198
-5.79
2.129
-5.84
DR(MAX)%
2.33
2.40
2.48
2.57
2.66
2.76
2.86
2.98
3.10
3.23
3.35
3.49
3.62
3.77
3.91
3.98
4.05
4.12
4.20
4.27
4.34
4.40
4.46
4.55
4.61
4.66
4.75
4.80
4.88
4.93
5.00
5.05
5.12
5.19
5.23
5.33
5.40
5.42
5.48
5.58
5.63
5.69
5.73
5.82
112