Hisense ADT-12UX4SSNL3 Technical & Service Manual page 102

Dc-inverter air conditioners, duct, cassette, ceiling & floor
Table of Contents

Advertisement

W
I
R
I
N
G
D
I
A
G
W
I
R
I
N
G
D
I
A
G
1
1
.
1
1
.
Press "ON/OFF"button or "CANCEL"button to quit parameter adaption state.
⑤Press "ON/OFF"button or "CANCEL"button to quit.
PARAMETER
PARAMETER
CODE
DESCRIPTION
Self Recovery of
1
Power Break
2
Temperature Type
Temperature Display
3
Type
Ratio of ambient
temperature sensed by
4
indoor temperature
sensor(cooling mode)
5
Filter Clean Indication
6
Filter Clean Time Set
7
Installation Height
Cooling Temperature
Compensation
8
(indoor unit
temperature sensor)
Heating Temperature
Compensation(indoor
9
unit temperature
sensor)
10
Static Pressure Set
Ratio of temperature
sensed by indoor
12
temperature
sensor( (Heating
mode)
Temperature
13
Adjustment-Cooling
Temperature
14
Adjustment-Heating
Access control, fire
25
protection, ON/OFF
function set
DC-� INVERTER AIR CONDITIONER TECHNICAL&SERVICE MANUAL
R
A
M
R
A
M
PARAMETER VALUE&REPRESENTATION
DATA
TYPE
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Integer
Character
Character
Integer
REPRESENTATION
(FUNCTION CODE)
0:Cancel Self Recovery of Power
Break function;
1:Self Recovery of Power Break;
others:invalid
0:Centigrade Temperature;
1:Fahrenheit Temperature;
others:invalid
0:Default display set temperature;
1: Default display room temperature;
others:invalid
0~10valid,more than 10 default is10
0:0%;1:10%;...;10:100%
0:Cancel Filter Clean prompt
function;
1:Set Filter Clean prompt function;
others:invalid
0~32,more than 32 default is
32*1000h
0~10m,more than 10m default is 10
0: 0℃; 1: -0.5℃; 2: -1℃; 3: -1.5℃;
4: -2℃; 5: -2.5℃; 6: -3℃; 7: -3.5℃;
8:-4℃;9:-4.5℃;10:-5℃;(the
wired controller displays integer with
the symbol)
0: 0℃; 1: -0.5℃; 2: -1℃; 3: -1.5℃;
4: -2℃; 5: -2.5℃; 6: -3℃; 7: -3.5℃;
8:-4℃;9:-4.5℃;10:-5℃;(the
wired controller displays integer with
the symbol)
1~240, function code=static pressure
more than the limit static pressure
default the limit static pressure,
Default is 0(default static pressure,
related to models)
0~10valid,more than 10 default is10
0:0%;1:10%;...;10:100%
-10~10℃(Single Character with
symbol)
-10~10℃(Single Character with
symbol)
=0,Access control, fire
protection functions are all disabled;
=1,Access control function is enabled;
=2,fire protection function is enabled;
=3,Access control, fire protection are
all enabled;
=4,ON/OFF function are all enabled.
NOTE
0-entirely use
temperature sensed by
wired remote controller;
10-entirely use
temperature sensed by
indoor unit
Duct type (DC motor )
0-entirely use
temperature sensed by
wired remote controller;
10-entirely use
temperature sensed by
indoor unit
Temperature displayed
on wired controller
Temperature displayed
on wired controller
100