Indoor unit parameter revise
Internal control parameter adjustment can be performed using wire remote controller YXE-C01U/YXE-C02U.
1. Connect wire remote controller with indoor unit
Step 1:Removing the upper cover of the wired controller
Insert a normal screw driver into the position,
and gently rotate it. In this way, the upper
cover can be easily removed.
Note:
Control board of the remote controller is placed on upper cover. Please protect it from being scratched during
removal and installation!
Step 2: Connecting wired controller with indoor unit
Indoor unit control board
2. Changing system parameter
确 定
OPERATION:
①Hold down both"MODE"button and"ADD.FUNC."button for 3 seconds, symbol
number blinking at the same time.
""
"button to adjust parameter number until display "17".
②Press"
And press "ENTER"button to entering system parameter adaption state,
parameter number blink.
③Select desired parameter code by pressing "
"ENTER" button to confirm.
④Select desired function code by pressing "
DC-� INVERTER AIR CONDITIONER TECHNICAL&SERVICE MANUAL
R
A
M
R
A
M
Upper cover of the wired controller
Lower cover of the
wired controller
"/ "
marked with:wired
"/ "
"button following the table below, and press
"button , and press "ENTER" button to confirm.
Connection cord of wired
controller (to indoor unit)
Wire remote controller
and parameter
symbol
stop blinking,
99