Dräger X-dock 5300
Dräger X-dock 6300/6600
Technical Manual
i

Advertisement

Table of Contents
loading

Summary of Contents for Dräger X-Dock 5300

  • Page 1 Dräger X-dock 5300 Dräger X-dock 6300/6600 Technical Manual...
  • Page 3: Table Of Contents

    Order list ....... . .23 Glossary ....... . .24 Dräger X-dock 5300/6300/6600...
  • Page 4: For Your Safety

    Indicates a potentially hazardous situation which, if not avoided, could result in physical injury, or damage to the product or environment. It may also be used to alert against unsafe practices. NOTICE Indicates additional information on how to use the product. Dräger X-dock 5300/6300/6600...
  • Page 5: Description

    Description Description Product overview X-dock 5300 (X-am) X-dock 5300 (Pac) X-dock 6300/6600 X-dock 5300/6300 X-dock 6600 X-dock 6300/6600 max. 10 00133286.eps Dräger X-dock 5300/6300/6600...
  • Page 6: Feature Description

    Dräger recommends not exceeding a hose length of another. A system consists of one master for 3 (X-dock 5300/ 10 m for the gas feed hoses. 6300) or 6 (X-dock 6600) test gases. The X-dock 5300 5.
  • Page 7: Basics

    The charging process is not interrupted. To switch to operating mode:  Tap the function key or  touch the touchscreen or  open or close a module flap.  Menu ► ◄ Favourites bar Dräger X-dock 5300/6300/6600...
  • Page 8: Logging Users In Or Out

    Select this button to access the previous screen. Log user in or out Select this button to log users in or out. The number in the symbol indicates the permission level (see chapter 7 on page 19). Dräger X-dock 5300/6300/6600...
  • Page 9: Configuring The Test Gas Inlet

    > Station gas configuration. 2. If necessary select Further options and to reset the gas An overview of the test gas connections is displayed. cylinder level indicator. 3. If required, configure other test gas inlets in the same way. Dräger X-dock 5300/6300/6600...
  • Page 10 More 10 m for the gas feed hoses. information on this can be found in the relevant sensor data 5. If required, configure other test gas inlets in the same way. sheets. Dräger X-dock 5300/6300/6600...
  • Page 11: Managing Tests

    The This function can be used to set whether or not a test or Test scheduler and Log-in mode test modes are configurable. calibration is carried out when a required test gas is not connected. Dräger X-dock 5300/6300/6600...
  • Page 12 Average shift values (time-weighted average) are generally limited to eight hours exposure per day per workplace for 5 days a week during a work lifetime. Further options ► 6. Save settings with OK. 2. Enter desired test name. Dräger X-dock 5300/6300/6600...
  • Page 13: Managing Instrument Profiles

    (max. 2 months) without a power supply must not be inserted into the station. Otherwise the as the internal buffer battery will run down.omatically once test cannot be fully evaluated correctly. the temperature is back in charging range. Dräger X-dock 5300/6300/6600...
  • Page 14: Station Self-Test

    Fast bump test including alarm testing information. Extended bump test incl. zero-point check and Remove the instrument from the module.  Test 2: EXT alarm testing. Calibration, alarm test, fresh air flushing and Test 3: CAL certificate. Dräger X-dock 5300/6300/6600...
  • Page 15: After Use

    Identify and rectify the error.  Repeat the test if necessary.  Overview of status LEDs Colour Status Meaning blue flashing Process in progress green flashing Test passed yellow flashing Test passed, with restrictions flashing Test failed/cancelled Dräger X-dock 5300/6300/6600...
  • Page 16: Menu

    Station gas configuration System configuration Date & time Data management Language Network System address Database DBMS address Info screen Update Service interval Devices Users Station event logger Export data logger Export certificates Mobile synchronization Mass storage device Dräger X-dock 5300/6300/6600...
  • Page 17: Managing Tests

    User profiles can be created, edited or deleted in this menu. 4. Where necessary, enter the Subnet Mask (default: Select  > Data management > Users. 255.255.255.0). The user profiles will be displayed. For more information see chapter 4.6 on page 8. Dräger X-dock 5300/6300/6600...
  • Page 18 X-dock Manager Online Help). 1. If necessary, connect the USB storage device to the USB port on the station. 2. Select > Data management > Mobile synchronization . The available target locations are displayed. 3. Select desired target location. Dräger X-dock 5300/6300/6600...
  • Page 19: Permission Level

    Perform preset tests in logged-in status Change password Define test Export data memory (station) Set Station gas configuration Show devices Define extended options Manage users Set date and time Perform SW update (station) Set Language Set network configuration Database operations Dräger X-dock 5300/6300/6600...
  • Page 20: Troubleshooting

    The firmware version of the affected gas Perform an update with the CC Vision PC Module X does not support firmware version error message. monitor is not compatible with X-dock. software. Dräger X-dock 5300/6300/6600...
  • Page 21: Maintenance

    There must not be any older firmware files on the USB data storage device. 2. Connect the USB data storage device with firmware update to the USB port on the station. The USB icon will appear in the status bar. Dräger X-dock 5300/6300/6600...
  • Page 22: Changing The Sealing Insert

    6. Squeeze external locking lugs in and insert the sealing insert into the module cover until the locking lugs engage. 7. Check that the sealing insert is fitted correctly in the module cover. 00733286.eps Dräger X-dock 5300/6300/6600...
  • Page 23: Technical Data

    Dimensions (H x W x D): Order No. Name and description Master approx. 3.54 x 5.70 x 9.84 inches Dräger X-dock 5300 X-am 125 83 21 880 (120 x 130 x 250 mm) Dräger X-dock 5300 Pac 83 21 881 Module approx.
  • Page 24: Glossary

    Database Management System Data logger Favourite HORN Horn Light-emitting diode Lower Explosive Limit Mass Storage Device Master SPAN Span calibration Software Response time test Time-weighted average UNDEF Unknown Unknown info Vibration ZCHECK Zero-point check ZERO Zero-point calibration Dräger X-dock 5300/6300/6600...
  • Page 25 Glossary Dräger X-dock 5300/6300/6600...
  • Page 28 Dräger Safety AG & Co. KGaA Revalstraße 1 23560 Lübeck, Germany Tel +49 451 882 0 Fax +49 451 882 20 80 www.draeger.com 90 33 286 - TH 4634.600 en © Dräger Safety AG & Co. KGaA Edition 07 - November 2013 (Edition 01 - August 2012) Subject to alteration...

This manual is also suitable for:

X-dock 6300X-dock 6600