DIELECTRIC STRENGTH: (at 15 to 35°C ambient, 10
to 85% relative humidity):
Between input and output: 3KV a-c for one minute,
cutout current 10ma.
Between input and ground: 2KV a-c for one minute,
cutout current 10ma.
Between output and ground: 500V a-c for one minute,
cutout current 20ma.

INSULATION RESISTANCE:

ground, output and ground, input and output, ±RC ter-
minals and input, ±RC terminals and output: 100
Megohms min. (500V d-c).

LEAKAGE CURRENT:

0.29mA typ, 0.45mA max at 100V a-c, 60 Hz (operat-
ing in conformance with Den-An).
0.40mA typ, 0.65mA max at 240V d-c and 60 Hz
(operating in conformance with IEC 950 and
UL1950).
SAFETY: Designed to meet EN 60950:2001 Assistance
for DEN-AN. U.S. UL 60950 First Edition.; Canada: CSA-
22.2 No.60950-1. Units are CE marked per the Low Volt-
age Directive (LVD), EN60950 73/23/EEC AND 93/68/
EEC. [The standards do not apply with DC input operation.]
COOLING: All models use forced convection, ball-bear-
ing fans, life expectancy 50,000+ hours. Natural convection
can be used if the load does not exceed 60% of max. (see
Figure 4). Simply disconnect the fan and install jumper J1
(see Figure 5); the alarm signals described above are dis-
abled and VDC ON lights red; overvoltage and open sense
line conditions still force unit shutdown. Contact Kepco's
Application Engineering for full-featured natural convec-
tion-cooled units.
EMI: Designed to meet FCC Class B (100-120V a-c) and
VDE 0871 Class B (220-240V a-c).
VIBRATION: (non-operating, one hour on each one of
the three axes):
5-10 Hz, 10 mm amplitude;
10-55 Hz, 2g acceleration.
SHOCK: (non-operating, one-half sinusoidal pulse, three
shocks to each axis):
Acceleration: 20g,
Duration: 11mS +5mS
OPERATING TEMPERATURE: See Figure 5.
STORAGE TEMPERATURE: -40
KEPCO, INC.  131-38 SANFORD AVENUE  FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000  FAX (718) 767-1102
021219
Between
input
and
o
o
C to +75
C.
http://www.kepcopower.com   email: hq@kepcopower.com
228-1621 REV 8
RELATIVE HUMIDITY: Operating and Storage: 10%
to 95% (wet bulb temp. <35
ALTITUDE:
0 -10,000 feet (operating),
0 - 65,000 feet (storage)
FUSE: Quick acting 5.0A, 250V; (5.2 x 20mm),
(Littelfuse P/N 215005PF,
Kepco P/N 541-0134).
DIMENSIONS: See Figure 7.
WEIGHT: 2.2 lbs, 1Kg.
WARRANTY: 5 years.
NOTE:
Safety agency approvals apply only to operation up to 40°C.
FIGURE 5. % OUTPUT POWER RATING VS. AMBI-
ENT TEMPERATURE
o
C non-condensing).