I N S T R U C T I O N M A N U A L
KEPCO
I — INTRODUCTION
The Kepco HSF-1UR 150 Watt Series hot swappable, high
frequency switching, plug-in power supplies with built-in
power factor correction (PFC) employ forward conversion
and are designed to operate in a fault tolerant power sys-
tem with either a-c or d-c input. A thermistor soft-start circuit
limits start-up surge; an input fuse (5A, 250V) protects
against shorts. Built-in OR-ing diodes (all models) and a
forced current share circuit (all models except 3.3V) allow
configuration of all models for hot-swap and parallel-redun-
dant N+1 operation.
The heart of the HSF-1UR Series is a Kepco RTW power
supply allowing them to weigh less and have improved effi-
ciency (input current) specifications over the older HSF-1U
Series. There are three options available: C, X and Y. Fea-
tures for all models are the same except as follows: C
option (-1URC) models include a current sensing resistor,
allowing external current monitoring within ±10% (contact
Kepco if greater accuracy required). X option (-1URX) mod-
els have remote control, the ability to turn the unit on and
off from a remote location. Y option models (-1URY)
include both current monitoring and remote on-off capabili-
ties.
TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, HSF-1UR 150W SERIES
MODEL
OUTPUT VOLTS, d-c (NOMINAL)
ADJUSTMENT RANGE
OVERVOLTAGE SETTING
OUTPUT CURRENT, NOMINAL
OVERCURRENT SETTING
OUTPUT POWER, MAX
(5)
switching (typ.)
RIPPLE AND NOISE
(mV p-p)
spike noise
0-40°C, 10-100% LOAD
(d-c—50MHz)
SENSE RESISTOR VALUE (milliohms)
(1) Overtemperature or overvoltage shuts down the output. Recover by recy-
cling a-c input (30 second delay required before resetting).
(2) 25°C, Nominal. Input.
(3) Hiccup mode operation. After the cause of overcurrent is removed, output
voltage recovers automatically.
(4) See power rating curve, Figure 4. Exceeding maximum power rating may
result in oscillation or a drop in output current or voltage.
KEPCO, INC. 131-38 SANFORD AVENUE FLUSHING, NY. 11355 U.S.A. TEL (718) 461-7000 FAX (718) 767-1102
©2019, KEPCO, INC
Data subject to change without notice
An ISO 9001 Company.
KEPCO SINGLE OUTPUT, 1U SIZE, 150 WATT
HOT SWAP PLUG-IN POWER SUPPLIES
HSF 3.3-30-1UR
HSF 5-30-1UR
3.3V
2.8 - 3.4V
(1) (2)
3.4 - 4.5 V
30A
(2) (3)
38.5 - 45.5A
(4)
100W
80
120
(6)
2.5
http://www.kepcopower.com email: hq@kepcopower.com
These power supplies are designed to be used with
Kepco's Series RA 19-1U rack adapters. The RA 19-1U
rack adapter accepts up to four 50-, 100- or 150-Watt units
(see Figure 1). All input/output connections are through a
24-pin connector that plugs in to the rack adapter. All exter-
nal connections are made through the rack adapter (refer
to the RA 19-1U manual which is available for free down-
load at:
www.kepcopower.com/support/opmanls.htm#ra19-1u
Seven models may be selected for outputs of 3.3, 5, 12, 15,
24, 28 or 48V (see Table 1).
When the input is cut off, the output is maintained for 20
milliseconds minimum. If the power supply shuts down due
to an output overvoltage condition, it is then necessary to
wait 60 seconds minimum before turning the unit on again.
EMI filtering is designed to meet FCC Class B rating and
VDE 0871 Class B rating. Table 1 contains specifications
that vary for each model of the HSF-1UR 150 Watt Series.
Common specifications are listed on page 4.
HSF 12-12-1UR
HSF 15-10-1UR
5V
12V
4.3 - 5.3V
9.8 - 13.0V
5.2 - 657V
13.2 - 15.2V
30A
12.5A
33.0-39.0A
13.7-16.3A
150W
150W
80
100
120
150
2.5
10
(5) Ripple and noise will be approximately 1.5 times higher in the operating temperature
range -10 to 0°C.
(6) Sense resistor included on C and Y Models only (see "Current Monitor" on page 2 for
details).
(7) Peak current and thermal protection applicable to 24V model only. See Figure 1 for
peak power requirements.
228-1621 REV 8
HSF-1UR
150W SERIES
HSF 24-6.3-1UR
15V
24V
12.3 - 16.5V
19.2 - 26.0V
16.8 - 18.8V
26.5 - 30.3V
6.3A
10A
(7)
(10A Peak
)
11.0-13.0A
10.5-13.5A
150W
151.2W
100
150
150
200
10
20
HSF 28-5.3-1UR
HSF 48-3.1-1UR
28V
48V
23.0 - 30.2V
40.0 - 52.2
31.5 - 34.8V
54.5 - 59.8V
5.3A
3.1A
5.94-7.02A
3.52-4.16A
151.2W
153.6W
150
200
200
300
20
30
1