Ap: / Unit-X, Fault Management - ABB FOX61 Series User Manual

Table of Contents

Advertisement

8.2.3

AP: / unit-x, Fault Management

ID
Fault Cause
SWM
Software Mismatch
SSWNA
Scheduled Software
Not Available
SWIN
Software Incompatible
With Network Element
PRC
PBUS Resource Con-
flict
EQM
Equipment Malfunction Equipment
HWIC
Hardware Incompatible
With Configuration
SWIC
Software Incompatible
With Configuration
GSW
General Software
Alarm
MFA
Maintenance Function
Active
UNAV
Unit Not Available
FOX61x
LEDE1
− "Main - Inventory",
− "Main - Logbooks", and
− "Main - Software"
management functions description, please refer to
Operation".
For the a description of the general aspects of the
− "Fault Management - Status", and
− "Fault Management - Configuration"
management functions, please refer to
The following table lists the fault causes of the current AP.
Table 8:
AP: / unit-x, Fault Management
Event Type
Traffic
Affecting
Equipment
Alarm
Equipment
Alarm
Equipment
Alarm
Processing
Error Alarm
Alarm
Equipment
Alarm
Equipment
Alarm
Equipment
Alarm
Communica-
tion Alarm
Equipment
Alarm
F O X C S T R E F E R E N C E
"1KHW002466 FOXCST
"1KHW002466 FOXCST
Default
Description
Severity
Minor
The running ESW does not match the
assigned ESW.
Minor
The ESW that is scheduled for installa-
tion is not available on the unit. Make
sure that the ESW is downloaded to the
unit.
Major
The running ESW is not compatible with
the version required by the NE type or
version.
Major
The PBUS access circuit of another TDM
unit in the subrack is defective.
Remove or unassign the other TDM units
in the subrack one by one until the alarm
is cleared. Replace the defective unit.
Critical
The LEDE1 controller detects any anom-
alies on the unit, e.g. a voltage is miss-
ing, a chip does not respond, etc.
Major
The plugged HW is not compatible with
the unit configuration HW stored in the
database. You may need to change the
HW or re-create the configuration for the
unit.
Major
The ESW running on the unit is not com-
patible with the unit configuration stored
in the database. You may need to
upgrade, or downgrade the ESW, or re-
create the configuration with the cur-
rently running ESW.
Major
An ESW internal error has been detected
that might inhibit the ESW from running
correctly.
Warning
A maintenance function has been acti-
vated by the operator.
Critical
The unit that is configured is either not
plugged or not recognized due to a fail-
ure.
Operation".
33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lede1

Table of Contents