ABB FOX61 Series User Manual page 39

Table of Contents

Advertisement

Operation Name
Parameter Name Range
Create Channel
Index
Layer Rate
n
Start Timeslot
Create Advanced
Channel ...
Create Advanced
Index
Channel
Timeslot(s)
Create Multiple
Channels ...
FOX61x
LEDE1
Table 12:
AP: / unit-x / port-y, Configuration - Synchronization (con-
0 ... 32
P12
P0_nc
1 ... 32
0 ... 31
0 ... 32
<Timeslot range>
F O X C S T R E F E R E N C E
Description / Details
The channel index is used to identify the chan-
nel.
0 is a reserved value used for the auto-assign-
ment of a channel index: The auto-assigned
index is the highest existing index number + 1.
In the FOXCST the default value is the autoas-
signed index number.
Unstructured 2048 kbit/s.
Automatically selected when the termination
mode is configured to "Transparent" or "Clock
Master".
Structured n x 64 kbit/s.
Automatically selected when the termination
mode is configured to "PCM30", "PCM30C",
"PCM31", "PCM31C", "V5 Uplink" or V5 Uplink
NCI".
Number of consecutive timeslots (valid for P0_nc
only). If the structured P12 signal, the channel is
belonging to, uses CAS the timeslot 16 will be
skipped automatically, e.g. a channel with n = 19
and start timeslot 1 will occupy timeslots 1 to 15
and 17 to 20 in a PCM30 signal.
The default value is the maximum of available
timeslots.
First timeslot of the first channel in the structured
P12 signal (valid for P0_nc only). The minimum
valid parameter value is 1
Open the FOXCST dialogue to create one chan-
nels with non-consecutive time slots in the struc-
tured P12 signal.
The termination mode must be configured to
"PCM30", "PCM30C", "PCM31", "PCM31C", "V5
Uplink" or V5 Uplink NCI".
The channel index is used to identify the chan-
nel.
0 is a reserved value used for the auto-assign-
ment of a channel index: The auto-assigned
index is the highest existing index number + 1.
In the FOXCST the default value is the autoas-
signed index number.
Configure the time slots to be used. A range of
consecutive time slots is defined by
"..", e.g. "5..9".
Different ranges are separated by
",", e.g. "1, 4, 5..9, 31"
If the structured P12 signal, the channel is
belonging to, uses CAS the timeslot 16 must not
be used, i.e. a range must be split so that it does
not include the timeslot 16, e.g. "1..15", "17..31".
Open the FOXCST dialogue to create one or
more channels.
The termination mode must be configured to
"PCM30", "PCM30C", "PCM31", "PCM31C", "V5
Uplink" or V5 Uplink NCI".
39