7

Operation and maintenance

7.1

Unit optical indicators

LED name
Colour
UNIT
Red
Green / Red
(blinking 1 Hz)
Green
Off
FOX61x
LEDE1
This section gives an overview of operational and maintenance aspects of
the LEDE1 unit. You will find the following information:
Description of the optical indicators found on the LEDE1 unit front (sec-
tion
"Unit optical indicators" (page
Diagnostic loop availability and handling (section
Generic maintenance functions of the unit (section
(page
29)).
Please note:
The operation functions described in this section assume a correctly config-
ured and operational LEDE1 unit.
LEDs on the front of the LEDE1 unit are used to indicate to the user the
alarm status summary of the unit and of the network traffic signals.
XXXXx
R1B
ANR_37900374
UNIT
TRAFFIC
Figure 7:
Fault indication LEDs on the LEDE1 unit
Table 6:
LED signalling on LEDE1
State
Meaning
Failure
Unit is not in service.
The unit is not able to provide the requested function due to
- equipment failure (total breakdown),
- mismatch of HW and SW.
Recovery from this error situation is done usually by replacement
of unit HW or ESW.
Booting or
Unit has not been taken in service yet or the unit has not been pro-
visioned.
waiting
Recovery from this situation is done by taking this unit into service
with FOXCST.
Running
Unit is up and running, it is ready to provide the required service.
Failure
System is not powered or outage of power supply on unit or outage
of LED.