ABB FOX61 Series User Manual page 45

Table of Contents

Advertisement

Operation Name
Parameter Name Range
CTP Configuration
Layer Rate
n
Timeslot(s)
Connected to CTPs Connection Index
Local Role
Remote CTP
Remote Role
Directionality
z-End Configuration Revertive Protection
Switching
CAS AIS Supervi-
sion
Switch-Over Log-
ging
FOX61x
LEDE1
Table 19:
AP: / unit-x / port-y / chan-z, Configuration - CTP
P12
P0_nc
0 ... 2 characters
0 ... 64 characters
0 ... 65'535
z-End
a-End Working
a-End Protecting
<MO address>
z-End
a-End Working
a-End Protecting
Bidirectional
Unidirectional
F O X C S T R E F E R E N C E
Description / Details
Unstructured 2048 kbit/s.
Structured n x 64 kbit/s.
Number of channel timeslots (valid for P0_nc
only).
Occupied timeslots in the structured P12 signal
(valid for P0_nc only).
Index of a connection assigned to the channel.
Without a connection the parameter is empty
The channel is the ending point of a connection.
Please refer to
"1KHW002467 FOX61x TDM
Services".
The channel is the working starting point of a
protected or unprotected connection.
The channel is the protecting starting point of a
protected connection.
Address string of a connections remote end.
Without a connection the parameter is empty
The CTP at the connections remote end is the
ending point of a connection.
Please refer to
"1KHW002467 FOX61x TDM
Services"
The CTP at the connections remote end is the
working starting point of a protected or unpro-
tected connection.
The CTP at the connections remote end is the
protecting starting point of a protected connec-
tion.
Directionality of the connection.
Enable revertive protection switching.
The z-End will preferably select the working a-
End.
Non-revertive protection switching is only availa-
ble for channels with the number of timeslots
n=1.
Non-revertive protection switching for n>1 will be
available in a future release,
Use CAS AIS as protection switching criterion.
CAS AIS supervision is only applicable with P0-
nc.
Enable the logging of the protection switch-over
events.
45

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lede1

Table of Contents