SPECIFICATIONS

6.1 Input and electrical

Differential inputs
Number of analog inputs
Input ranges
Max. number of instruments without
temperature sensor
Max. number of instruments with Pt100
Max. number of instruments with 10k NTC
Max. voltage allowed on input
Resolution
Single ended inputs
Number of analog inputs
Input ranges
Max. number of 10k thermistors
Max. voltage allowed on input
Resolution
Digital inputs
Number of inputs
Input selections
Max. voltage allowed
Max. input frequency
Logic level
Serial inputs
Number of RS-485 inputs
Supported models
General specifications
Input offset differential max.
Inaccuracy differential
Inaccuracy single ended
Memory
Internal power supply
Power connection (PWR)
Solar power connection (SOLAR)
Battery power connection (BATT)
Charger connection (CHARGER)
Battery out (BATOUT)
Power out (PWROUT)
Power consumption
Power via USB
Temperature range
Dimensions
Protection
Mounting
RTC accuracy (without synchronization)
Time synchronization
GSM modem specifications
Model 2017-2018 2G GPRS only
Model 2019 4G with 2, 3G fall back depending on
operator
4
A9 – A12
8
19, 38, 78,156, 312, 625, 1250, 2500mV
4
2-wire signal
1
2-wire signal & 4 wire Pt100 thermistor
4
2-wire signal & 2 wire 10k NTC to single ended
5V
24bit
4
AIN1 – AIN4
2
0 – 2.5V on AIN1 & AIN2
0 – 3V on AIN3 & AIN4
4
2-wire
5V
12bit
4
DIN1 – DIN4
3
Time, Frequency, Counter
15V
1500Hz
3V
CMOS, DIN4 0.5V for CDS3
8
Use one common RS-485 connection
5
SMPxx, SGRxx, SHP1, SUVx, RT1, DustIQ, Lufft
WSxxx UMB, IMT MB silicon sensor
0.5µV
0.05%
0.1%
SD card
512MB included, 4GB max FAT formatted
And 16GB FAT32 formatted
6x AA battery
4 – 24V
General input for 6x AA batteries or other source
DC
12 – 20V
From optional solar panel
DC
12V
12V Pb battery, max. charge 750mA
DC
6 – 13V
Used to charge the 12V Pb battery
DC
12V -750mA
Constant power to drive instruments
Follows PWR
Switched power max. 200mA
From 6x AA battery
1mA standby, 7mA short burst when storing
or PWR
data max. 100mA with GSM modem working
Doesn't include powered instruments
Possible
Only with opened box, for logger setup
-40 to 60ºC
170x145x50mm
IP65
⌀ 45mm
Pole / mast mounting
10ppm
once a day over
If ModemInterval is not zero
internet
Cinterion MC75i
www.gemalto.com/m2m/solutions/downloads
www.gemalto.com/m2m/solutions/modules-
Cinterion PLS62-W
terminals/industrial-plus/pls62-w