8.3 Connecting to differential inputs

8.4 Connecting to single ended inputs

It's possible to connect up to four sensors on the analog single ended inputs AIN1 to AIN4.
Please note that AIN3 and AIN4 can be used to connect sensors which have a slightly higher voltage output up to 3Vdc (like
Kipp & Zonen UVS or CSD3 sensors).
Since the ADC always uses 12 bit on the single ended input; the lowest bit on AIN1 & 2 equals 0,61035 mV and on AIN3 & 4
the lowest bit equal 0,73242 mV
The LOGBOX SE allows you to connect up to 4 sensors on the differential
analog inputs AIN9 to AIN12 which have a selectable input from 19mV up to
2500mV.
-AIN9+ and AIN9-
(first sensor)
-AIN10+ and AIN10-
(second sensor)
-AIN11+ and AIN11-
(third sensor)
-AIN12+ and AIN12-
(fourth sensor)