Parts Description

A. ELECTRIC MOTOR:
The motor is used to power the pump. It contains a thermal overload protector. If
the motor overheats for any reason, the thermal overload protector will shut it down in order to prevent
the motor from being damaged.
AIR COMPRESSOR PUMP:
piston moving up and down in the cylinder.
B. AIR TANK: The tank is used to store the compressed air.
C. TANK PRESSURE GAUGE:
not adjustable by the operator and does not indicate line pressure.
D. AIR PRESSURE REGULATOR:
Turn the knob clockwise to increase pressure and counterclockwise to decrease pressure.
WARNING
Never exceed the maximum working pressure of the tool.
E. REGULATED PRESSURE GAUGE: The gauge is used to measure the regulated outlet pressure.
F. AIR LINE OUTLET: The outlet is used to connect air hose with quick connector.
G. AIR TANK BALL VALVE: The ball valve is used to remove moisture from the air tank after the unit is
shut off.
WARNING
Never attempt to open the drain valve when the tank pressure is more than 10 PSI.
H. PRESSURE RELIEF VALVE:
preset leve motor, it will automatically pop open. You can also pull the ring on the valve to open.
I. ON/OFF SWITCH:
This switch turns on the compressor and is operated manually. When in the ON
position, it allows the operated manually. When in the ON demand. ALWAYS set this switch to OFF
when the compressor is not being used and before unplugging the compressor.
J. POWER CORD:
This product is for use on a nominal 120-volt circuit and should be grounded. A cord
with a grounding plug as illustrated must be used. Make sure that the product is connected to an outlet
that has the same configuration as the plug (see Figure 1). No adapter should be used with this
Check with a licensed electrician if the grounding instructions are not
understood or there is doubt as to whether the product is properly
grounded. Do not modify the plug provided. If it will not fit the outlet,
have the proper outlet installed by a licensed electrician.
DANGER
Improper installation of the grounding plug will result in a risk
of electric shock. If repair or replacement of the cord or plug is
necessary, do not connect the grounding wire to either flat blade
terminal. The grounding wire is in the green outer surface.
8
The pump is used to compress the air and discharge it into the tank via the
The gauge is used to measure the stored air pressure level of the tank. It is
The regulator is used to adjust line pressure to the tool you are using.
The valve is used to prevent system the system. If the pressure reaches the
Grounded
outlet
Plug
Grounding Pin