6 – Configuration Using ISiCL
Table 6-5. Valid :DCS:CONFIG?: Parameters and Responses
Possible
Parameter
Response
DS0,<m>,
<p>,<c>
FLAGS1
ELOF
ELOS
EFLOF
EYEL
EITU
ELOD
EAIS
EBER
ACT1
ACT2
ACT3
ACT4
ACT5
ACT6
MAPIND
FLAGS2
RECOVERY
BER
FLAGS3
DLY1
DLY2
GatesAir
Intraplex Products
Returns the source of the DS0 specified in the command:
= map number (0–7)
<m>
= port number (1–6)
<p>
= channel number (1–24)
<c>
For example, the command line
:DCS:CONFIG?:DS0,0,1,1;
would return a response like this one:
*OK
DS0,0,1,1 = <p>,<c>;
This response indicates that the data on T1 port 1, channel (time slot) 1 is
coming from the T1 on port
If you leave any one of the
a wildcard and returns all of the matching DS0 mappings, which can result in a
very long response:
:DCS:CONFIG?:DS0,0,1;
would return all 24 DS0 mappings for map 0, port 1.
:DCS:CONFIG?:DS0,0;
would return all 24 DS0 mappings for each of the six ports in map 0.
:DCS:CONFIG?:DS0;
would return all 24 DS0 mappings for each of the six ports in every
map
(24 × 6 × 8 = 1152 channels).
Enable port switching on loss of frame.
Enable port switching on loss of (frame) synchronization.
Enable fast loss of frame.
Enable yellow (remote) alarm.
Enable ITU compatibility mode.
Enable port switching on loss of data.
Enable port switching on AIS alarm.
Enable on port switching on BER threshold exceeded.
Port 1 active/not active.
Port 2 active/not active.
Port 3 active/not active.
Port 4 active/not active.
Port 5 active/not active.
Port 6 active/not active.
DCS Map Change Indicator active/not active.
Recovery time delay
Bit error ratio threshold
Switch time delay for port 1
Switch time delay for port 2
T1 CrossConnect Installation & Operation Manual
Description
, channel
.
<p>
<c>
,
, or
values blank, the DCS treats it like
<m>
<p>
<c>
Version 2
6-13