6 – Configuration Using ISiCL
Example 1: Suppose that you want to set time slot 3 to have robbed-bit signaling. All the bits in the
bit masks for n2 and n3 would remain set to zero. In the bit mask grouping for n1, to set the third bit
for time slot 3 (TS3) to one, specify a value for n1 of 0x04 (hexadecimal format). ISiCL accepts only
hexadecimal format, not decimal format. Table 6-3 gives the values to set time slot 3 to robbed-bit
signaling.
Table 6-3. RBS Values for Time Slot Examples
Time
Parameter
Slot
Value
TS3
n1
n2
n3
TS13
n1
n2
n3
TS23
n1
n2
n3
Example 2: Suppose that you want to set time slot 13 to have robbed-bit signaling. All the bits in the
bit masks for n1 and n3 would remain set to zero. In the bit mask grouping for n2, to set the fifth bit
for time slot 13 (TS13) to one, specify a value for n2 of 0x10 in hexadecimal format. Table 6-3 gives
the values to set time slot 13 to robbed-bit signaling.
Example 3: Suppose that you want to set time slot 23 on port 1 to have robbed-bit signaling. All the
bits in the bit masks for n1 and n2 would remain set to zero. In the bit mask grouping for n3, to set
the seventh bit for time slot 23 (TS23) to one, specify a value for n3 of 0x40 in hexadecimal format.
Table 6-3 gives the values to set time slot 23 to robbed-bit signaling.
The SET command line for Example 3 is:
:DCS:SET:RBS,1=0x00,0x00,0x40;
The syntax for the query command for one port is:
:DCS:CONFIG?:RBS,p;
The syntax for the query command for all ports is:
:DCS:CONFIG?:RBS;
A query command for all ports in Example 3, in which time slot 23 is selected for robbed-bit signaling,
would return this response with the hexadecimal time slot encoding for all ports.
Response to :DCS:CONFIG?:RBS; command:
*OK
Port 1:
0x00,
Port 2:
0x00,
Port 3:
0x00,
Port 4:
0x00,
Port 5:
0x00,
Port 6:
0x00,
GatesAir
Intraplex Products
Binary
Hexadecimal
Format
Format
00000100
0x04
00000000
0x00
00000000
0x00
00000000
0x00
00010000
0x10
00000000
0x00
00000000
0x00
00000000
0x00
01000000
0x40
0x00,
0x40
0x00,
0x00
0x00,
0x00
0x00,
0x00
0x00,
0x00
0x00,
0x00;