GatesAir Intraplex T1 DCS-9530 CrossConnect System Installation And Operation Manual page 88

Table of Contents

Advertisement

6 – Configuration Using ISiCL
Table 6-2. Valid
:DCS:SET:
Parameter
DLY6
Delay
DS0,M,TxP,TxC
DS0 Remapping
TxC
DS0 Remapping
EAIS
All ones failure
EBER
Bit error rate
EFLOF*
Fast loss of frame
EITU
International
Telecommunications
Union (ITU)
compatibility
ELOD
Loss of data
ELOS
Loss of sync
EXTEN,<e>
Enable external
inputs
EYEL
Yellow (remote)
alarm failure
FTYPE, P
Frame type P = port
number (1 to 6)
GatesAir
Intraplex Products
Parameters and Legal Values (continued)
Function
Legal Value
0 to 100 (ms)
RxP, RxC
RxP, RxC
ON
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON or OFF
ON
OFF
SF
ESF
T1 CrossConnect Installation & Operation Manual
Sets Parameter To
Switch time delay, port 6
DS0 remapping parameters where:
M=Map number (0–7)
TxP=Tx Port number (1 to 6)
TxC= Tx Port Channel number (1 to 24)
RxP= Rx Port number (1 to 6, 0=constant)
RxC= Rx Port Channel number (1 to 24; if RxP=0,
then RxC=the constant value)
Note: A constant can be entered in decimal or
hexadecimal format as shown in this example:
decimal
hexadecimal
If a constant FFH is selected, enter it as follows: 0,FFH
DS0 remapping parameter where:
M=Map number (0–7)
TxP=Tx Port number (1 to 6)
TxC= Tx Port Channel number (1 to 24)
RxP= Rx Port number (1 to 6, 0=constant)
RxC= Rx Port Channel number (1 to 24; if RxP=0,
then RxC=the constant value)
Note: A constant can be entered in decimal or
hexadecimal format as
decimal
hexadecimal
If a constant FFH is selected, enter it as
Enable all ones failure
Disable all ones failure
Enable bit error rate failure
Disable bit error rate failure
(Must be OFF)
Enable ITU compatibility mode
Disable ITU compatibility mode
Enable loss of data failure
Disable loss of data failure
Enable loss of sync failure
Disable loss of sync failure
Set external input (0 to 7) ON or OFF, where
<e> = external input
Enable yellow alarm failure
Disable yellow alarm failure
Super Frame
Extended Super Frame
Version 2
255
FFH or 0XFF
255
FFH or 0XFF
0,FFH
6-7

Advertisement

Table of Contents
loading

Table of Contents