6 – Configuration Using ISiCL
Table 6-4. Valid
:DCS:STATUS?:
Possible
Parameter
Response
COUNT4
CLOCK SOURCE
CLOCK IN USE
CLOCK
CHANGES
VERSION
COUNT5
PORT 5 BER
PORT 6 BER
COUNT6
MAP 5 COUNT
MAP 6 COUNT
EXTERNAL
INPUTS
DIAG,<n>
CRBL/ARBL
CRYEL/ARYEL
CRCL/ARCL
CRLOS/ARLOS
CBPV/ABPV
CRESS/ARESS
CBERS/ABERS
CMFOS/AMFOS
FLAGS1
LOF1
LOD1
AIS1
BER1
LOF2
LOD2
AIS2
BER2
LOF3
LOD3
AIS3
BER3
LOF4
LOD4
AIS4
BER4
EXTA
GatesAir
Intraplex Products
T1 CrossConnect Installation & Operation Manual
Parameters and Responses (continued)
The user-configured desired timing source (
The timing source currently being used.
The number of times the timing source was changed.
The software version number of the DCS firmware.
The bit error ratio for T1 port 5.
The bit error ratio for T1 port 6.
The number of times Map 4 was used.
The number of times Map 6 was used.
Returns a value in the format "bbbbbbbb:" where each "b" represents the state
of an external input (1=on, 0=off).
<n> selects which port information is displayed. No entry displays all six ports.
Current/accumulated unframed all ones.
Current/accumulated receive yellow (remote) alarm.
Current/average number of carrier loss (CL) alarms.
Current/average number of loss of signal alarms.
Current/average number of bi-polar violations (BPVs).
Current/average number of elastic store slips.
Current/average number of seconds the BER threshold has been exceeded.
Current/average number of MFOS alarms.
Loss of frame on framer 1.
Loss of data on framer 1.
All ones signal on framer 1.
Bit error rate exceeded on framer 1.
Loss of frame on framer 2.
Loss of data on framer 2.
All ones signal on framer 2.
Bit error rate exceeded on framer 2.
Loss of frame on framer 3.
Loss of data on framer 3.
All ones signal on framer 3.
Bit error rate exceeded on framer 3.
Loss of frame on framer 4.
Loss of data on framer 4.
All ones signal on framer 4.
Bit error rate exceeded on framer 4.
External clock alarm (requested external clock no longer in use).
Description
) and status.