T1 CrossConnect Installation & Operation Manual
Version 2
Throughput Delay
DS0 Interfaces
(CrossConnect Server)
Maps
Supported
Switch Time
Indicator
Lights
Contact
Closures
Diagnostics
Functionality
Interface
Nominal Power
Requirements
Nominal Power
Consumption
Operating
Temperature
Humidity
Dimensions
Regulatory
Compliance
Specifications are subject to change without notice.
8-2
One to three T1 frames 125 to 375µS
Two frames average 250µS
Optional 4-wire voice frequency (VF), 2-wire VF, synchronous,
asynchronous, and variable rate data, program audio, and video
Eight: Two normal service maps and six alternate service maps
configurable to switch based on T1 port failure (BER, LOS, AIS, LOF),
external contact closure inputs or ASCII command
Protection switching delay, programmable down to 1 millisecond
Shelf Power, Normal, Alert, Alarm
DCS Port Status, Alert, Alarm
Shelf Alert, Alarm
DCS Alert, Alarm, Active Map Indicators
T1 and time slot loopback
Remote programming and monitoring, PC-based graphical user interface
and command line interfaces
Off-line copying and editing of cross-connect maps
RS-232C and RS-485 asynchronous
3 RU
Universal AC standard
Optional -48VDC, -24VDC, or +24VDC
Optional hot-standby redundant supply
1 RU
Universal AC
DCS-9500/9530: 5 watts
DCS-9560: 8 watts
DCS-9565: 11 watts
0° - 50°C
0% to 90% non-condensing
3 RU: 5.25" x 14.5" x 19" rack-mount
1 RU: 1.75" x 14.5" x 19" rack-mount
CE Approved
UL 1950
FCC Part 15, FCC Part 68
CS-03
8-Specifications