MAINTENANCE
Maintenance of the ventilator means regular cleaning of the ventilator surfaces of dust and cleaning or replacement of the filters.
Accessing the main units for servicing and maintenance as follows:
Disconnect the socket connectors and pull the cord to remove the cartridge from the air duct. Remove the filters from the cartridge.
Clean the filters as often as required, but at least 3 times a year.
After expiry of the period set for the hour meter (factory setting 90 days) the filter replacement indicator
•
control panel display.
Wash the filters, let those dry out and install the dry filters inside the air duct.
•
Vacuum cleaning is allowed.
•
The filter rated service life is 3 years.
•
•
Contact the Seller for spare filters.
Even regular technical maintenance may not completely prevent dirt
accumulation on the regenerator and the fan.
Clean the regenerator regularly to ensure its high heat
•
recovery efficiency.
Clean the regenerator with a vacuum cleaner at least once a
•
year.
16
V127EN-01.indd 16
DISCONNECT THE UNIT FROM POWER SUPPLY BEFORE ANY MAINTENANCE OPERATIONS!
TwinFresh Easy
appears on the
www.ventilation-system.com