Removing the insulation
The insulation can be removed, to facilitate handling in
confined spaces.
Unscrew the lifting eye at the top.
Lift off the plastic top and the top insulation.
Remove the joining plates holding the insulated jacket
halves together. Do not use any tools when dismant-
ling.
Unhook and remove the insulated jacket halves, the
outer diameter of the heater becomes approx. 200
mm less without the insulated jackets.
The figure shows VPA 300/200
-Cu with insulation
Carry out assembly in reverse order.
Install the enclosed insulation plugs around each connec-
tion. Finally, fit all the enclosed cover discs on each con-
nection by pressing them over the connections.
NOTE
Fit the cover discs and the insulation plugs be-
fore installing the pipe.
NOTE
In certain cases, more insulation plugs are en-
closed than are required.