Removing the insulation
The insulation can be removed, to facilitate handling in
confined spaces.
Unscrew the lifting eye at the top.
■
Lift off the plastic top and the top insulation.
■
Remove the joining plates holding the insulated jacket
■
halves together. Do not use any tools when dismant-
ling.
Unhook and remove the insulated jacket halves, the
■
outer diameter of the heater becomes approx. 200
mm less without the insulated jackets.
The figure shows VPA 300/200
-Cu with insulation
Carry out assembly in reverse order.
Install the enclosed insulation plugs around each connec-
tion. Finally, fit all the enclosed cover discs on each con-
nection by pressing them over the connections.
NOTE
Fit the cover discs and the insulation plugs be-
fore installing the pipe.
NOTE
In certain cases, more insulation plugs are en-
closed than are required.
10
Chapter 3 |
For the Installer
Do not use any tools when dis-
mantling the joining plate.
Insulation removed
VPA 300/200