Troubleshooting; Maintenance; Weber ® Spider /Insect Screens - Weber Spirit E-210 Owner's Manual

Lp gas grill
Hide thumbs Also See for Spirit E-210:
Table of Contents

Advertisement

10
PROBLEM
Burners burn with a yellow or orange fl ame, in
conjunction with the smell of gas.
Some countries have regulators with an excess gas
fl ow safety device.
Symptoms:
Burners do not light. -or- Burners have a small
fl ickering fl ame in the HI position. -or-
Barbecue temperature only reaches 250˚ to 300˚
in the HI position.
Burner does not light, or fl ame is low in HI
position.
Experiencing fl are-ups:
CAUTION: Do not line the bottom tray with
aluminum foil.
Burner fl ame pattern is erratic. Flame is low when
burner is on HI. Flames do not run the whole
length of the burner tube.
Inside of lid appears to be "peeling." (Resembles
paint peeling.)
If problems cannot be corrected by using these methods, please contact the Customer Service Representative in your area using the contact information on our web
®
site. Log onto www.weber.com
.
WEBER
®
SPIDER /INSECT SCREENS
Your Weber
®
gas barbecue, as well as any outdoor gas appliance, is a target for spiders
and other insects. They can nest in the venturi section (1) of the burner tubes. This
blocks the normal gas fl ow, and can cause the gas to fl ow back out of the combustion
air opening. This could result in a fi re in and around the combustion air openings, under
the control panel, causing serious damage to your barbecue.
The burner tube combustion air opening is fi tted with a stainless steel screen (2) to
prevent spiders and other insects access to the burner tubes through the combustion air
openings.
We recommend that you inspect the Spider/Insect screens at least once a year.
(See Section "Annual Maintenance".) Also inspect and clean the the Spider/Insect
screens if any of the following symptoms should ever occur:
1)
The smell of gas in conjunction with the burner fl ames appearing yellow and lazy.
2)
Barbecue does not reach temperature.
3)
Barbecue heats unevenly.
4)
One or more of the burners do not ignite.
Failure to correct the above mentioned symptoms may result
in a fi re, which can cause serious bodily injury or death, and
cause damage to property.

TROUBLESHOOTING

Inspect Spider / Insect Screens for possible obstructions.
(Blockage of holes.)
The excess fl ow safety device, which is part of the
barbecue to cylinder connection, may have activated.
Is LP fuel low or empty?
Is fuel hose bent or kinked?
Does the Left burner light with a match?
Are you preheating barbecue in the prescribed manner?
Are the cooking grates and Flavorizer
coated with burned-on grease?
Is the bottom tray "dirty" and not allowing grease to fl ow
into catch pan?
Are burners clean?
The lid is stainless steel, not paint. It cannot "peel". What
you are seeing is baked on grease that has turned to
carbon and is fl aking off. THIS IS NOT A DEFECT.

MAINTENANCE

DANGER
CHECK
Clean Spider / Insect Screens. (See Section "Annual
Maintenance")
To reset the excess fl ow safety device turn all burner
control knobs and the cylinder valve to OFF. Disconnect the
regulator from the cylinder. Turn burner control knobs to HI.
Wait at least 1 minute. Turn burner control knobs to OFF.
Reconnect the regulator to the cylinder. Turn cylinder valve
on slowly. Refer to "Lighting Instructions".
Refi ll LP cylinder.
Straighten fuel hose.
If you can light the Left burner with a match, then check the
Crossover
All burners on high for 10 to 15 minutes for preheating.
®
bars heavily
Clean thoroughly. (See Section "Cleaning")
Clean bottom tray
Clean burners. (See Section "Maintenance".)
Clean thoroughly. (See Section "Cleaning".)
CURE
®
ignition system.
(1)
(2)
WWW.WEBER.COM
®

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spirit sp-310Spirit sp-210Spirit e-310