Remove Control Panel And Burner Control Knobs; Check For Gas Leaks - Weber Spirit E-210 Owner's Manual

Lp gas grill
Hide thumbs Also See for Spirit E-210:
Table of Contents

Advertisement

REMOVE CONTROL PANEL AND BURNER CONTROL KNOBS

You will need: Phillips screwdriver.
1) Remove control knobs.
2) Remove screws with a Phillips screwdriver
3) Pull up igniter button until it sticks in the up position and remove control panel
from grill.
4) Replace control panel when Leak Check is completed.

CHECK FOR GAS LEAKS

Do not use an open fl ame to check for gas leaks. Be sure
there are no sparks or open fl ames in the area while you
check for leaks. Sparks or open fl ames will result in a fi re or
explosion, which can cause serious bodily injury or death
and damage to property.
WARNING: You should check for gas leaks every time you
disconnect and reconnect a gas fi tting.
Note: All factory-made connections have been thoroughly checked for gas leaks. The
burners have been fl ame-tested. As a safety precaution, however, you should recheck
all fi ttings for leaks before using your Weber
loosen or damage a gas fi tting.
WARNING: Perform these leak checks even if your barbecue
was dealer or store assembled.
You will need: a soap and water solution, and a rag or brush to apply it.
Note: Since some leak test solutions, including soap and water, may be slightly
corrosive, all connections should be rinsed with water after checking for leaks.
Make sure side burner is OFF. Remove valve control knob and screws. Remove
porcelain top.
To perform leak checks: open cylinder valve by turning the cylinder valve hand-wheel
anticlockwise.
WARNING: Do not ignite burners when leak checking.
Check for leaks by wetting the connections with the soap and water solution and
watching for bubbles. If bubbles form or if a bubble grows, there is a leak.
Check:
1)
Hose to manifold connection.
WARNING: If there is a leak at connection (1), retighten the
fi tting with a spanner and recheck for leaks with soap and
water solution.
If a leak persists after retightening the fi tting, turn OFF the gas. DO NOT
OPERATE THE BARBECUE. Contact the Customer Service Representative in your
area using the contact information on our web site. Log onto www.weber.com
2)
Regulator to Cylinder connection
3)
Valves to manifold connections
4)
Hose to regulator connection
WARNING: If there is a leak at connections (2), (3) or (4) turn
OFF the gas. DO NOT OPERATE THE BARBECUE.Contact
the Customer Service Representative in your area using the
contact information on our web site. Log onto www.weber.
com
®
. When leak checks are complete, turn gas supply OFF
at the source and rinse connections with water.
WWW.WEBER.COM
®
GAS INSTRUCTIONS
DANGER
®
gas barbecue. Carraige and handling may
SPIRIT E/SP-
210 & 310
(1)
SPIRIT E/SP-
210 & 310
®
.
*The grill illustrated may have slight
differences than the model purchased.
(2)
(3)
(1)
(2)
(3)
(4)
7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spirit sp-310Spirit sp-210Spirit e-310

Table of Contents