7.14.4 Engine oil – Sample extraction and analysis
Preconditions
☑ MTU Fluids and Lubricants Specifications (A001061/..) are available.
Special tools, Material, Spare parts
Designation / Use
MTU test kit
DANGER
Components are moving or rotating.
Risk of crushing, danger of parts of the body being caught or pulled in!
• Operate the engine at low load only. Keep clear of the danger zone of the engine.
WARNING
Oil is hot.
Oil can contain residue/substances which are harmful to health.
Risk of injury and poisoning!
• Allow the product to cool to below 50 °C before beginning work.
• Wear protective clothing, protective gloves and goggles/safety mask.
• Avoid contact with skin.
• Do not inhale oil vapor.
WARNING
High level of engine noise when the engine is running.
Risk of damage to hearing!
• Wear ear protectors.
Take engine oil sample and ana-
lyze
1.
With the engine running at operating temper-
ature, loosen screw on automatic oil filter by
1 to 2 turns.
2.
Drain approx. 2 liters engine oil to flush out
the oil sludge.
3.
Drain approx. 1 liter engine oil into a clean
container.
4.
Close screw.
5.
Using the equipment and chemicals in the
MTU test kit, analyze the engine oil for:
• Dispersing capacity (spot test);
• Water content;
• Dilution with fuel
MS150045/03E 2018-08 | Lube Oil System, Lube Oil Circuit | 219
Part No.
Qty.
5605892099/00
1