3.7 16V4000M73 engine data: EPA Tier 2, engine-mounted heat
exchanger, copper-based alloy intercooler
Explanation:
DL Reference value: Continuous power
BL Reference value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated, without change (e.g. of power setting)
N Not yet defined value
- Not applicable
X Applicable
Reference conditions
Engine model
Application group
Intake air temperature
Raw water inlet temperature
Barometric pressure
Site altitude above sea level
POWER-RELATED DATA (power ratings are net brake power as per ISO 3046)
Number of cylinders
Rated engine speed
Fuel stop power ISO 3046
GENERAL CONDITIONS (for maximum power)
Number of cylinders
Intake depression (new filter)
Intake depression, max.
MODEL RELATED DATA (basic design)
Number of cylinders
Cylinder arrangement: V angle
Bore
Stroke
Cylinder displacement
Total displacement
Number of inlet valves per cylinder
Number of exhaust valves per cylinder
A
A
A
L
MS150045/03E 2018-08 | Technical Data | 79
16V4000
M73
1B
°C
25
°C
25
mbar
1000
m
100
16
rpm
1970
kW
2560
16
mbar
15
mbar
30
16
Degrees
90
mm
170
mm
190
Liters
4.31
Liters
68.96