Item
Setting
REM COM RATE
Setting value: 9.6, 19.2, *38.4,
57.6 Kbps
Set
communications
speed for
REMOTE IN (RS-
232C) connector
RS232C COM
Setting value: 9.6, 19.2, *38.4,
RATE
57.6 Kbps
Set
communications
speed for RS-
232C connector
PLAYER DF
Select *DF or NDF.
MODE
Select the same
frame count mode
(DF or NDF) as
that of the material
RECORDER DF
Select *DF or NDF.
MODE
Select the same
frame count mode
(DF or NDF) as
that of the material
REC MODE
*INSERT: Insert mode
Select edit mode
ASSEMBLE: Assemble mode
AUDIO LAG
LAG CALC CH1: Select one of *CH1,
CALC
CH2, CH3, CH4
Select reference
LAG CALC CH2: Select one of CH1,
channel for pitch
*CH2, CH3, CH4
correction (channel
LAG CALC CH3: Select one of CH1,
from which to
CH2, *CH3, CH4
extract pitch data)
LAG CALC CH4: Select one of CH1,
CH2, CH3, *CH4
LAG CALC CH5: Select one of *CH5,
CH6, CH7, CH8
LAG CALC CH6: Select one of CH5,
*CH6, CH7, CH8
LAG CALC CH7: Select one of CH5,
CH6, *CH7, CH8
LAG CALC CH8: Select one of CH5,
CH6, CH7, *CH8
CC READ
*21Line: Detect closed caption data
added to line 21 and perform time
Select whether or
adjustment processing.
not to read closed
caption data
VANC: Detect closed caption data
added to VANC and perform time
adjustment processing.
CC WRITE
*21line: Output to line 21.
Select where to
VANC: Output to VANC.
write closed
21line&VANC: Output to line 21 and
caption data
VANC.
CC WRITE LINE
Setting value: *9 to 19
Select lines when
writing to VANC
Item
Setting
BLANK LINE
ALL LINE
Turn video signal
- - -: Specify the blanking for each
vertical blanking
line separately.
on and off
*BLANK: Blank all lines regardless of
the settings of LINE 9 ... LINE 21.
THROUGH: Turn off blanking for all
lines regardless of the settings of
LINE 9 ... LINE 21.
LINE 9 ... LINE 21
Specify blanking for lines 9 to 21
separately.
*BLANK: Blank on.
THROUGH: Turn off blanking.
REMOTE/LOCAL
KEY INHIBIT: Lock (*ON) or do not
MODE
lock (OFF) front panel of this unit
when unit is under remote control.
Enable or disable
remote control via
REMOTE CONTROLL: Enable (*ON)
RS-232C, and
or disable (OFF) remote control of
lock or do not lock
editing operations.
the front panel of
KEYINHIBIT MODE: Lock all panel
this unit while
operations on this unit (ALL
under remote
DISABLE), or enable the STOP
control
button only (*STOP key ENABLE).
VERSION
SYS: Display CPU software version
Software version
DSP: Display DSP software version
display (CPU,
(DSP1 to 4)
programmable
PLD: Display PLD software version
devices, DSPs)
(PLD1 to 2)
CONNECTION
PLY-VTR CONNECTION
STATUS
OK: 9-pin remote communication is
connection status
good.
display
NG: No 9-pin remote communication
to player.
REC-VTR CONNECTION
OK: 9-pin remote communication is
good.
NG: No 9-pin remote communication
to recorder.
SDI INPUT SIGNAL
OK: SDI input signal is valid.
NG!!: NO SIGNAL' SDI input signal
is no or invalid.
EXT REF INPUT
OK: EXT-REF input video signal is
valid.
NG!!, NO SIGNAL: EXT-REF input
video signal is no or invalid.
REC-VTR RECINHIBIT
OK: Recorder can record.
NG!!: REC INHIBIT: Recorder
cannot record.
NG!!: No communication to recorder.
PLY-VTR 9pinREMOTE
OK, REMOTE MODE: Player 9-pin
remote mode is on.
!!, LOCAL MODE: Player 9-pin
remote mode is off.
NG!!: No communication to player.