Load the scale into the scale guide
Remove the splitter screw (see figure 1) from the scale guide body by turning until the flats on
the screw are parallel to the slot.
Separate the backing paper from the first 40mm of scale and feed it into the scale guide
as shown in Figure 2 and lock in place by turning through 90°.
Relocate the splitter screw behind the backing paper as shown in Figure 2.
Push the scale carefully through to the end of scale mark, ensuring that it does not stick to the
mounting surface until it is in position.
NOTE: To prevent the scale sticking to the mounting surface during this operation it may be
necessary to re-apply approximately 20 mm of backing paper to the end of the scale before
inserting through scale guide. This can then be removed before fitting end clamps.
Attach the end of the scale to the mounting surface with light finger pressure.
Apply the scale
Traverse the axis through its full travel at a slow, steady speed.
While moving the axis apply a light finger pressure to the scale behind the scale guide
to attach it to the mounting surface.
Gently pull the backing paper away from in front of the scale guide as it is separated.
Remove the scale guide
When the axis has reached the limit of its travel, lock the axis in place and unbolt the
scale guide from the readhead mounting bracket.
Withdraw the scale guide along the scale whilst applying the remaining scale using
light finger pressure.
Ensure complete adhesion of the scale to the mounting surface by applying firm finger pressure
along the full length of the scale from the centre outwards to each end.
Fit end clamps part number A-9523-4015 (refer to Scale installation guide M-9517-2855 for details).
Scale handling precautions
Avoid aggressive solvents
refer to Scale installation guide
M-9517-2855 for details
Scale surface
is immune to
handling
Plastic extrusion for
lengths under 1 m
DO NOT remove the scale for refitting or use elsewhere once it has been applied to the mounting surface.
For worldwide contact details, please visit our
main website at www.renishaw.com/contact
© 1999-2004 Renishaw plc
Issued 0904
T
+44 (0)1453 524524
F
+44 (0)1453 524901
E
uk@renishaw.com
www.renishaw.com
No sharp objects
Renishaw reserves the right to change specifications without notice
Do not twist
>100 mm
Keep coils tight
during storage
Reel for lengths
over 1 m
*M-9541-0035-03*

Advertisement

loading

This manual is also suitable for:

Rgh25