Safeway water Premium Series Owner's Manual page 20

Two tank 1-plus-1 water conditioner & whole house filters
Table of Contents

Advertisement

By-pass valve in
closed position.
Press and hold the
position, with time counting down on the display. (Refill is the first cycle
in the regeneration process.)
Press and release the
the next position.
Note: REFILL is the first cycle with Premium Series valves. Therefore, skip
past "refill" on the initial start up to prevent carbon and other media fines
from going into the brine tank.
The valve should be programmed as a "Conditioner – Filter", and the
display will read "Conditioning", with 120 minutes counting down for the
refill and dwell time to dissolve the salt
Press
REGEN
After initiating the filter backwash, open the filter's inlet slowly 1/3 to fill
mineral tank.
Allow air to escape (listen until spurting stops).
Once water flows from drain, open inlet fully.
Continue backwash until water runs clear. (Repeated backwash cycles
may be necessary to fully rinse the carbon or other filter media.)
Note: Because treated water is used to refill the brine tank, this process is
the first step in the regeneration process. Also, the filter will backwash
during the 120 minute dwell time for the salt to dissolve prior the brine rinse
cycle to remove hardness minerals from the ion exchange resin.
Start Up
Once the installation is
complete, initiate an
immediate regen to
start up system in with
inlet and outlet valves
closed.
REGEN
button until the valve advances to the
REGEN
and the valve will advance to
button again ,and the valve will advance to
BACKWASH.
20
Slowly open valve
inlet 1/3 to fill tank.
FILL

Hide quick links:

Advertisement

Table of Contents
loading

Related Products for Safeway water Premium Series

Table of Contents