Valve Programming
Assuming you selected "Conditioner-Filter", continue as
follows:
•
XR 1000 will appear on the screen. This is 8% resin. For
Premium Systems select XR3000, for 10% resin and
press NEXT
•
Select the resin volume and press NEXT (0.75 cu. ft.
with 8x44 tank; 1.0 cu. ft. with 10x44 tank; 1.5 cu. ft.
with 10x54 tank; or 2.5 cu. ft. with 13x52)
•
Enter water hardness (GPG) from water test and press
NEXT
•
Enter the level of Iron from water test and press NEXT
•
Select DAYS OVERRIDE (14 is typical) and press NEXT
Note: If "Iron" is entered in set-up, override is limited
to 5 or 6 days.
•
TDS (select "low" if under 800 or "high" if over 800).
Press NEXT
•
Select Regenerate Type (Na Cl is typical for Sodium
Chloride salt or KCL for Potassium Chloride.) Press
NEXT
•
Select capacity at regen (set on 50% for greater
efficiency). Press NEXT
(Continued)
14