Parallel kit for programmable dc power supplies (8 pages)
Summary of Contents for TDK-Lambda Genesys Series
Page 1
Series Programmable DC Power Supplies G1.7 ÷ 5kW in 1U 60-100V / 17-85A The manual covers kit options: G/P-6U-60-100V PARALLEL KIT INSTRUCTION MANUAL IA902-04-01A *Z0022573* Z0022573...
Page 2
General Parallel kit is supplied separately from the power supply packing according to order. The usage of parallel kit is according to customer's needs. Advanced Parallel For parallel connection, refer to advanced parallel chapter in the series User Manual. Product Safety Instructions Safety approvals are valid for single unit only.
Page 3
Image Component Quantity M8 x 25 Hexagon Bolt, Stainless Steel Plain Washer, M8, Stainless Steel Helical Spring-Lock Washer, M8, Stainless Steel Hexagon Nut, M8, Stainless Steel 1.4.1.2 Installation Steps 1. Attach connection plates, one on each side of the power supplies, using 24 pan head screws, 24 helical spring-lock washers and 24 plain washers as illustrated in Figure 1.
Page 4
2. Attach output bus bars plates, one on each sextet terminals, using 12 hexagon bolts, 24 plain washers, 12 helical spring-lock washers and 12 hexagon nuts as illustrated in Figure 2. Output Bus Bar Plate Hexagon Nut, M8, Stainless Steel Helical Spring-Lock Washer, M8, Stainless Steel M8 x 25 Hexagon Bolt, Stainless Steel Plain Washer, M8, Stainless Steel...